Parameter

Description

 

 

Standards

IEEE 802.3 (100BASE-FX/ Fast Ethernet)

 

 

 

EIA/TIA RS-232

 

 

 

EIA/TIA-574

 

 

Regulatory Compliance for Emission

FCC Part 15 of Class A & CE approved

 

 

Ports

1x fiber single mode/multi-mode

 

 

 

1x 9-pin serial connector; D-sub, male

 

 

Max Distance

Fiber:

up to 120,000 meters (74.5 miles)

 

 

 

Serial:

up to 15 meters (50 ft.)

 

 

Max Data Rate

Fiber:

100 Mbs

 

 

 

Serial:

115.2 Kbps (asynchronous)

 

 

Signals

TxD, RxD, CTS, RTS, DTR, DSR, RI,

 

 

 

DCD, GND

 

 

Safety Compliance

CISPR22/EN5022 Class A + EN55024;

 

 

 

EN60950 Class A; FCC Class A and CE

 

 

 

Mark

 

 

 

Power Consumption

3.4 watts

 

 

Ingress Protection

IP30

 

 

 

MTBF

123,778

 

 

 

Power Source

External, 9 to 48VDC @ 1A

 

 

Size (width x depth x height)

2 x 3.9 x 4.7 in (50 x 100 x120mm)

 

 

Weight

0.90 kg (2 lbs)

 

 

Operating Temperature

0 to 70ºC (32 to 158ºF)

 

 

Storage Temperature

-20 to 80º C (-4 to 176ºF)

 

 

Operating Humidity

5% to 90% (non-condensing), altitude 0-

 

 

 

10,000 ft

 

 

 

 

 

 

 

 

Continued on next page

Image 83
Contents Page Page Table of Contents Transition Networks Iii Intentionally Blank May be required to take adequate preventative measures Trademark Copyright restrictions FCC warningCE Mark About this product and manual About this product and manual Box contents The box should include the followingPerformance Observe this caution could result in EMI problemsEquipment, or injury to persons Damage to the Device ServerSDSFE31xx-100 Industrial Device Server Transition Networks Intentionally Blank See Section SDSFE31xx-100 Industrial Device ServerThis section These are the topics TopicOverview FeaturesGeneral description Standard SDSFE31xx-100 Industrial part numbersFunctions Physical descriptionParts FunctionsDevice server parts and functions Physical descriptionIntentionally Blank Topic See Section InstallationThis section These are the topicsDevice Service mounting location Mounted DIN Rail Clip DIN rail clip and DIN rail mountingStep Action DIN rail clip and DIN rail mountingDevice Server Grounding Screw Grounding the Device ServerRedundant Power Connections Connecting power to the Device ServerPolarity. See Figure Connecting power to the Device ServerTurn the external power source OFF Strip the power wires as requiredWired Terminal-Block Plug Inserted Into Device Server Terminal-block plug wiring Step ActionAlarm Relay Contacts Connecting an alarm fixtureIndications Connecting an alarm fixtureFault Fiber Cable Connections Connecting fiber cablesDB-9 cable Connecting DB-9 cableInstallation Section for DB-9 cable pinoutsDip Switch Settings and Explanations DIP SwitchesIntentionally Blank Section Operations LEDs Light emitting diodes LEDsLogin Dialog Box Device Server configurationWeb access Device Server configurationSystem Restart Configuration softwareSystem information submenu Master information submenu Configuration softwareSerial Port Transfer Configuration Submenu Display Configuration menu optionsSerial Device Connection to a Host via Ethernet Network Serial port config submenu Submenu Item DescriptionSerial Tunneling Submenu Item Description RS-232 Port Connection Status Submenu DisplaySee Figure User configSubmenu Firmware Upgrade Submenu Http Firmware File Name Captured FW upgrade via Http Step ActionIndex Page System information Display FW upgrade via HttpFW upgrade via Tftp Step Action Configuration System Backup File Display Backup File Restore Display Snmp Communities Display Snmp configuration menu Snmp communities submenuIP Trap Parameters and Descriptions Describes the fields on the IP Trap Manager displayIP trap manager submenu Will be erased System restoreSystem Restore ResetIntentionally Blank This are the topics Section Serial IP Redirector SoftwareSection Serial IP redirect software description Needed? Step Action What isInstallation Wizard Dialog Box Installing serial IP redirector softwareSoftware Destination Folder Dialog Box Installing serial IP redirector softwareSelect Features Dialog Box Ready to Install Application Dialog Box Step Action Upgrading serial IP redirector software Software upgradesSerial IP Control Panel Dialog Box Creating virtual COM portsSelect Ports Dialog Box Creating virtual COM portsVirtual Port Configuration COM Port 7 Configuration Wizard If the wizard is Setting button will be active. See FigureIf the wizard FailsSerial/IP Port Monitor If the wizard is successful Step ActionIntroduction Section TroubleshootingTroubleshooting problem and corrective action table Problem Potential Cause Potential Solution Troubleshooting problem and corrective action tableThis section provides copper and fiber cable specifications Section Cable SpecificationsPinouts Copper DB-9 RS-232serial cable specificationsWhat is RS-232 SpecificationsFiber Cable Specifications Fiber cable and optic specificationsParameterSpecification Intentionally Blank Section Contact Us, Warranty Conformity Information Contact us Declaration of Conformity Conformity declarationWarranty Warranty Canadian Compliance informationCompliances RegulationsTo the Public Telephone NETWORK. Failure to observe this Compliance informationAccordance with European Union Directive 2002/96/EC Portion of this documentIntentionally Blank Parameter Description Appendix a Technical SpecificationSDSFES31xx-100 specifications, notices, and warnings This warning could result in an eye injury or blindness SDSFES31xx-100 specifications, notices, and warningsSubchapter J applicable at the date of manufacture Could result in damage to equipmentIndex COM Port ConfigurationPacket Mode