Multiquip DCA-15SPXU4 Lug Nut Torque Requirements, Start all wheel lug nuts by hand

Page 39

DCA-15SPXU4 —TRAILER MAINTENANCE

Lug Nut Torque Requirements

It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows:

1.Start all wheel lug nuts by hand.

2.Torque all lug nuts in sequence (see Figure 39). DO NOT torque the wheel lug nuts all the way down.Tighten each lug nut in 3 separate passes as defined by Table 15.

3.After first road use, retorque all lug nuts in sequence. Check all wheel lug nuts periodically.

Table 15. Tire Torque Requirements

Wheel Size

First Pass

Second Pass

Third Pass

 

FT-LBS

FT-LBS

FT-LBS

 

 

 

 

12"

20-25

35-40

50-65

 

 

 

 

13"

20-25

35-40

50-65

 

 

 

 

14"

20-25

50-60

90-120

 

 

 

 

15"

20-25

50-60

90-120

 

 

 

 

16"

20-25

50-60

90-120

 

 

 

 

Figure 39. Wheel Lug Nuts

Tightening Sequence

NOTE

NEVER use an pneumatic air

 

gun to tighten wheel lug nuts.

DCA-15SPXU4— OPERATION MANUAL — REV. #0 (03/31/11) — PAGE 39

Image 39
Contents Model DCA-15SPXU4 Diesel engine exhaust and some Page Table of Contents Page DCA-15SPXU4 Specifications Dimensions DCA-15SPXU4 Dimensions TOP, Side and FrontHazard Symbols DCA-15SPXU4 Safety Message Alert SymbolsDCA-15SPXU4 Safety Message Alert Symbols Carbon monoxide gas General SafetyDCA-15SPXU4 Rules for Safe Operation Injury PeopleDCA-15SPXU4 Rules for Safe Operation Maintenance SafetyBattery Safety Death Guidelines section in this manual Towing and Transporting SafetyPage DCA-15SPXU4 Installation Mounting DCA-15SPXU4 InstallationOutdoor Installation Indoor InstallationOpen Delta Excitation System GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-15SPXU4 Major ComponentsDCA-15SPXU4 Generator Control Panel 12 11DCA-15SPXU4 Generator Control Panel Output Terminal Familiarization DCA-15SPXU4 Output Terminal Panel FamiliarizationDCA-15SPXU4 Output Terminal Panel Familiarization 120VAC Gfci ReceptacleL5-30RTwist Lock 120VAC Receptacle DCA-15SPXU4 Output Terminal Panel Familiarization Connecting LoadsGenerator Amperage Single Phase LoadDCA-15SPXU4 Load APPLICATION/MAXIMUM Amperage Motors and motor-driven1Ø 120 Output Terminal Lug Voltages Ammeter gauge will only Show a reading when the OutputDCA-15SPXU4 Gauge READING/TERMINAL Panel Connections UNV Terminal Output VoltagesRefilling the Fuel System Circuit BreakersLubrication Oil Fuel CheckRefueling Refueling ProcedureOperation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/WaterAlternator BatteryBattery Cable Installation WiringDirect exhaust away from nearby personnel DCA-15SPXU4 Generator START-UP ProcedureBefore Starting Engines exhaust contains harmful emissionsOn position Figure DCA-15SPXU4 Generator START-UP ProcedureEmergency Shutdown Procedure Normal Shutdown ProcedureFuel Addition General Inspection Air CleanerAir Cleaner with Dust Indicator If Equipped Service DailyReplacing Oil Filter Cleaning the Fuel StrainerAir Removal Check Oil LevelTo ensure adequate starting Battery Charger JacketWater Heater Power ConnectionsCheck the wheel and drum for free rotation DCA-15SPXU4 -TRAILER MaintenanceBrake Adjustment BrakesTires/Wheels/Lug Nuts TireWear/InflationSuspension Start all wheel lug nuts by hand Lug Nut Torque RequirementsGenerator Wiring Diagram DCA-15SPXU4 Generatorwiring DiagramEngine Wiring Diagram DCA-15SPXU4 Enginewiring DiagramDCA-15SPXU4 -TROUBLESHOOTING Engine DCA-15SPXU4 -TROUBLESHOOTING Engine Generator Troubleshooting DCA-15SPXU4 -TROUBLESHOOTING GeneratorFailure Diagnosis Lamp Code DCA-10SPX4 -TROUBLESHOOTING PRE-HEAT Lamp CodesHERE’S HOW to GET Help