If your generator is trailer mounted, please read the towing and safety requirements listed below.

Towing and Transporting Safety

To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.

The following list of safety precautions should be followed when towing your generator:

CAUTION - FOLLOWTOWING REGULATIONS

Check with your local county or state safety towing regulations, in addition to meeting Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

ALWAYS shutdown engine before transporting.

Drain fuel from generator fuel tank before towing.

If generator is mounted on a trailer, make sure trailer complies with all local and state safety transportation laws. Follow the listed Towing & Transporting Safety guidelines for basic towing techniques.

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a "Safety Chain".

ALWAYS attach trailer’s safety chains to towing vehicle properly.

ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.

DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place chock blocks underneath wheel to prevent rolling, while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

Avoid sudden stops and starts. This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when transporting.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place support blocks underneath the trailer’s bumper to prevent tipping, while parked.

Avoid sharp turns to prevent rolling.

DO NOT transport generator with fuel in tank.

NOTE

For more saftey tips, see the trailer saftey

 

guidelines section in this manual.

PAGE 14 — DCA-15SPXU4— OPERATION MANUAL — REV. #0 (03/31/11)

Image 14
Contents Model DCA-15SPXU4 Diesel engine exhaust and some Page Table of Contents Page DCA-15SPXU4 Specifications DCA-15SPXU4 Dimensions TOP, Side and Front DimensionsDCA-15SPXU4 Safety Message Alert Symbols Hazard SymbolsDCA-15SPXU4 Safety Message Alert Symbols Injury People General SafetyDCA-15SPXU4 Rules for Safe Operation Carbon monoxide gasMaintenance Safety DCA-15SPXU4 Rules for Safe OperationBattery Safety Death Towing and Transporting Safety Guidelines section in this manualPage DCA-15SPXU4 Installation Indoor Installation DCA-15SPXU4 InstallationOutdoor Installation MountingOutput Terminal Panel GeneratorGenerator Control Panel Open Delta Excitation SystemDCA-15SPXU4 Major Components Major Components12 11 DCA-15SPXU4 Generator Control PanelDCA-15SPXU4 Generator Control Panel DCA-15SPXU4 Output Terminal Panel Familiarization Output Terminal FamiliarizationL5-30RTwist Lock 120VAC Receptacle DCA-15SPXU4 Output Terminal Panel Familiarization120VAC Gfci Receptacle Connecting Loads DCA-15SPXU4 Output Terminal Panel FamiliarizationMotors and motor-driven Single Phase LoadDCA-15SPXU4 Load APPLICATION/MAXIMUM Amperage Generator AmperageUNV Terminal Output Voltages Ammeter gauge will only Show a reading when the OutputDCA-15SPXU4 Gauge READING/TERMINAL Panel Connections 1Ø 120 Output Terminal Lug VoltagesFuel Check Circuit BreakersLubrication Oil Refilling the Fuel SystemRefueling Procedure RefuelingCoolant Antifreeze/Summer Coolant/Water Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation FreezingWeatherWiring BatteryBattery Cable Installation AlternatorEngines exhaust contains harmful emissions DCA-15SPXU4 Generator START-UP ProcedureBefore Starting Direct exhaust away from nearby personnelDCA-15SPXU4 Generator START-UP Procedure On position FigureNormal Shutdown Procedure Emergency Shutdown ProcedureService Daily General Inspection Air CleanerAir Cleaner with Dust Indicator If Equipped Fuel AdditionCheck Oil Level Cleaning the Fuel StrainerAir Removal Replacing Oil FilterBattery Charger JacketWater Heater Power Connections To ensure adequate startingBrakes DCA-15SPXU4 -TRAILER MaintenanceBrake Adjustment Check the wheel and drum for free rotationSuspension Tires/Wheels/Lug NutsTireWear/Inflation Lug Nut Torque Requirements Start all wheel lug nuts by handDCA-15SPXU4 Generatorwiring Diagram Generator Wiring DiagramDCA-15SPXU4 Enginewiring Diagram Engine Wiring DiagramDCA-15SPXU4 -TROUBLESHOOTING Engine DCA-15SPXU4 -TROUBLESHOOTING Engine DCA-15SPXU4 -TROUBLESHOOTING Generator Generator TroubleshootingDCA-10SPX4 -TROUBLESHOOTING PRE-HEAT Lamp Codes Failure Diagnosis Lamp CodeHERE’S HOW to GET Help