Multiquip operation manual DCA-15SPXU4 Specifications

Page 6

 

 

DCA-15SPXU4 — SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

Table 1. Generator Specifications

 

 

 

 

 

 

 

Model

DCA-15SPXU4

 

 

 

 

 

 

 

Type

Revolving field, self ventilated, open protected type synchronous

 

 

generator

 

 

 

 

 

 

 

 

 

 

Phase

Single Phase 3-Wire

 

 

 

 

 

 

 

 

Standby Output

 

16.5 KW

 

 

 

 

 

 

 

 

Prime Output

 

 

15 KW

 

 

 

 

 

 

 

Voltage

240V/120

 

 

 

 

 

 

 

 

Frequency

 

 

60 Hz

 

 

 

 

 

 

 

Speed

1800 rpm

 

 

 

 

 

 

 

 

Power Factor

 

1.0

 

 

 

 

 

 

 

 

Aux. AC Power

2.4 KW @120 VAC Single Phase, 60 Hz

 

 

(GFCI)

 

 

 

 

 

 

 

 

 

 

 

 

 

Aux. AC Power

3.6 KW@120 VAC Single Phase, 60 Hz

 

 

(L5-30R)

 

 

 

 

 

 

 

 

 

 

 

 

 

Aux. AC Power

7.2 KW@240 VAC Single Phase, 60 Hz

 

 

(L6-30R )

 

 

 

 

 

 

 

 

 

 

 

 

Aux. AC Power

12 KW@240 VAC Single Phase, 60 Hz

 

 

(CS6369)

6 KW@120 VAC Single Phase, 60 Hz

 

 

 

 

 

 

 

 

Table 2. Engine Specifications

 

 

 

 

 

 

 

Model

KUBOTA V2203-M

 

 

 

 

 

 

 

Type

4 Cycle, water-cooled, swirl combustion chamber type

 

 

 

 

 

 

 

No. of Cylinders

4 cylinders

 

 

 

 

 

 

 

Bore x Stroke

3.43 in. x 3.64 in. (87 mm x 92.4 mm)

 

 

 

 

 

 

 

Rated Output

27.1 HP/1800 rpm

 

 

 

 

 

 

 

Displacement

134.1 cu. in. (2,197 cc)

 

 

 

 

 

 

 

 

Starting

 

Electric

 

 

 

 

 

 

 

Coolant Capacity

2.09 gal. (7.9 liters)

 

 

 

 

 

 

 

Lube Oil Capacity

2.00 gal. (7.6 liters)

 

 

 

 

 

 

 

Fuel Tank Capacity

16.4 gal. (62 liters)

 

 

 

 

 

 

 

 

Fuel Consumption

1.37 gal. (5.2 L)/hr at full load

 

1.08 gal. (4.08 L)/hr at 3/4 load

 

 

 

 

 

 

 

0.83 gal. (3.14 L)/hr at 1/2 load

 

0.62 gal. (2.34 L)/hr at 1/4 load

 

 

 

 

 

 

 

 

 

 

 

Battery

12V- 65AH (27:525A)

 

 

 

 

 

 

 

Fuel

#2 Diesel Fuel

 

 

 

 

 

 

 

 

Dry Weight

 

 

577 kg

 

 

 

 

 

 

 

 

Total Weight

 

 

649 kg

 

 

 

 

 

 

 

PAGE 6 — DCA-15SPXU4— OPERATION MANUAL — REV. #0 (03/31/11)

Image 6
Contents Model DCA-15SPXU4 Diesel engine exhaust and some Page Table of Contents Page DCA-15SPXU4 Specifications DCA-15SPXU4 Dimensions TOP, Side and Front DimensionsDCA-15SPXU4 Safety Message Alert Symbols Hazard SymbolsDCA-15SPXU4 Safety Message Alert Symbols Injury People General SafetyDCA-15SPXU4 Rules for Safe Operation Carbon monoxide gasMaintenance Safety DCA-15SPXU4 Rules for Safe OperationBattery Safety Death Towing and Transporting Safety Guidelines section in this manualPage DCA-15SPXU4 Installation Indoor Installation DCA-15SPXU4 InstallationOutdoor Installation MountingOutput Terminal Panel GeneratorGenerator Control Panel Open Delta Excitation SystemDCA-15SPXU4 Major Components Major Components12 11 DCA-15SPXU4 Generator Control PanelDCA-15SPXU4 Generator Control Panel DCA-15SPXU4 Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-15SPXU4 Output Terminal Panel Familiarization 120VAC Gfci ReceptacleL5-30RTwist Lock 120VAC Receptacle Connecting Loads DCA-15SPXU4 Output Terminal Panel FamiliarizationMotors and motor-driven Single Phase LoadDCA-15SPXU4 Load APPLICATION/MAXIMUM Amperage Generator AmperageUNV Terminal Output Voltages Ammeter gauge will only Show a reading when the OutputDCA-15SPXU4 Gauge READING/TERMINAL Panel Connections 1Ø 120 Output Terminal Lug VoltagesFuel Check Circuit BreakersLubrication Oil Refilling the Fuel SystemRefueling Procedure RefuelingCoolant Antifreeze/Summer Coolant/Water Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation FreezingWeatherWiring BatteryBattery Cable Installation AlternatorEngines exhaust contains harmful emissions DCA-15SPXU4 Generator START-UP ProcedureBefore Starting Direct exhaust away from nearby personnelDCA-15SPXU4 Generator START-UP Procedure On position FigureNormal Shutdown Procedure Emergency Shutdown ProcedureService Daily General Inspection Air CleanerAir Cleaner with Dust Indicator If Equipped Fuel AdditionCheck Oil Level Cleaning the Fuel StrainerAir Removal Replacing Oil FilterBattery Charger JacketWater Heater Power Connections To ensure adequate startingBrakes DCA-15SPXU4 -TRAILER MaintenanceBrake Adjustment Check the wheel and drum for free rotationTires/Wheels/Lug Nuts TireWear/InflationSuspension Lug Nut Torque Requirements Start all wheel lug nuts by handDCA-15SPXU4 Generatorwiring Diagram Generator Wiring DiagramDCA-15SPXU4 Enginewiring Diagram Engine Wiring DiagramDCA-15SPXU4 -TROUBLESHOOTING Engine DCA-15SPXU4 -TROUBLESHOOTING Engine DCA-15SPXU4 -TROUBLESHOOTING Generator Generator TroubleshootingDCA-10SPX4 -TROUBLESHOOTING PRE-HEAT Lamp Codes Failure Diagnosis Lamp CodeHERE’S HOW to GET Help