Multiquip DCA-220SSJ Generator OUTPUTS/ Gauge Reading, Maximum Amps, Ammeter gauge will only

Page 45

DCA-220SSJ — GENERATOR OUTPUTS/ GAUGE READING

Maximum Amps

Table 10 shows the maximum amps the generator can pro- vide. DO NOT exceed the maximum amps as listed.

Table 10. Generator Maximum Amps

Model

DCA220SSJ

 

 

Rated Voltage

Maximum Amps

 

 

Single Phase

488.9 amps (4 wire)

120 Volt

 

 

 

Single Phase

244.4 amps (4 wire)

240 Volt

 

 

 

Three Phase

529 amps

240 Volt

 

 

 

Three Phase

264 amps

480 Volt

 

 

 

How to Read the Output Terminal Gauge.

The AC ammeter and AC voltmeter change-over switches on the control panel DO NOT effect the generator output. They are provided to help observe how much power is being supplied, produced at the UVWO terminals lugs.

When the voltage change-over board (Figure 16) is jumpered for 3Ø, 240V operation place the AC Voltmeter Change- Over Switch (Figure 17) to the W-U position and the AC Ammeter Change-Over Switch (Figure 19) to the U or W position. Use the AC voltmeter or AC ammeter (Figures 18 and 20) to read the output on the selected leg of the UVWO terminals.

Figure 17. AC Voltmeter

Figure 18. AC Voltmeter Gauge

Change-Over Switch

(Volt reading on W-U Lug)

Figure 19. AC Ammeter

Figure 20. AC Ammeter

Change-Over Switch

(Amp reading on U lug)

The ammeter gauge will only

NOTEshow a reading when the Output Terminal Lugs are connected to a load and in use.

DCA-220SSJ— OPERATION AND PARTS MANUAL — REV. #1 (03/22/07) — PAGE 45

Image 45 Contents
Model DCA-220SSJ Parts List NO. C18703004042 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-220SSJ Specifications Dimensions DCA-220SSJ Dimensions TOP, Side and FrontHazard Symbols DCA-220SSJ Safety Message Alert SymbolsThis generator, other property, or DCA-220SSJ Safety Message Alert SymbolsDCA-220SSJ Rules for Safe Operation General SafetyElectrical Safety DCA-220SSJ Rules for Safe OperationGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyDCA-220SSJ Generator Decals Generator Decals Cont inued DCA-220SSJ Generator DecalsTypical Generator Grounding Application DCA-220SSJ InstallationIndoor Installation Outdoor InstallationWhen connecting the generator MountingEngine Operating Panel GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-220SSJ Major ComponentsDisplay Parameters Menu Button Press this button to enter or exit menu screensFirst Time Start Up DCA-220SSJ Diagnostic DisplayMain Menu Navigation Selecting a LanguageStored Fault Codes Diagnostic CodeEngine Configuration Data To make a selectionDCA-220SSJ Diagnostic Display 24 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 Display will return to the single or four parameter screen Auxiliary Gage FaultActive Fault Codes Shut Down Codes Backlight AdjustmentCode from an engine control unit the single or four DamageContrast Adjustment IntensityIs highlighted Select Units Setup 1- Up DisplayOnce the Setup 1-up Display menu icon has been Setup menuUp display function Automatic Scan on Select the 4-Up Custom Setup from the 4-Up Setup menu Setup 4-Up DisplayUtilities information and troubleshooting Gage Data is selected the PowerView will When the gage data has cleared, the displayVersion currently in the diagnostic display Half duplexTouch the Menu button again to return to the Main MenuTouch the Menu Button Highlight it, then touch Enter Glossary Troubleshooting information DCA-220SSJ Diagnostic DisplayECU did not respond to the PowerView request No parameter selected for this 4- UP quadrantDCA-220SSJ Generator Control Panel Fuel Gauge Indicates amount of diesel fuel available DCA-220SSJ Engine Operating PanelAuto On/Off Engine Controller Mpec DCA-220SSJ Engine Operating PanelOutput Terminal Familiarization DCA-220SSJ Output Terminal Panel Familiarization 100VAC Gfci Receptacles DCA-220SSJ Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadDCA-220SSJ Load Application Motors and motor-drivenDCA-220SSJ Generator Outputs DCA-220SSJ Generator OUTPUTS/ Gauge Reading How to Read the Output Terminal GaugeMaximum Amps Ammeter gauge will onlyUvwo Terminal Output Voltages DCA-220SSJ Output Terminal Panel Connections3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages3Ø-480V Uvwo Terminal Output Voltages DCA-220SSJ Output Terminal Panel Connections1Ø-480V Uvwo Terminal Output Voltages 1Ø-277V Uvwo Terminal Output VoltagesCircuit Breakers DCA-220SSJ PRE-SETUPLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorPlace the engine speed switch in the LOW down position DCA-220SSJ Generator START-UP Procedure ManualBefore Starting Engines exhaust contains harmful emissionsEngine Speed Switch High When the generator is set Auto mode, the generator will Starting Auto ModeNo Load Tachometer GaugePlace the Mpec Control Switch in the Auto position Place the engine speed switch in the High positionDCA-220SSJ Generator SHUT-DOWN Procedures Normal Shutdown ProcedureEmergency Shutdown Procedure DCA-220SSJ Maintenance Engine Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterTo ensure adequate starting DCA-220SSJ Maintenance HEATER/CHARGERTrailer Maintenance DCA-220SSJ Maintenance TrailerBrake Adjustment DCA-220SSJ Maintenance TrailerBrakes Check the wheel and drum for free rotationTires/Wheels/Lug Nuts TireWear/InflationSuspension DCA-220SSJ Maintenance Trailer Lug Nut Torque RequirementsStart all wheel lug nuts by hand DCA-220SSJ -TRAILERWIRING Diagram Generator Wiring Diagram DCA-220SSJ Generatorwiring DiagramEngine Wiring Diagram DCA-220SSJ Enginewiring DiagramGenerator Troubleshooting DCA-220SSJ -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-220SSJ -TROUBLESHOOTING Engine ControllerDCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 DCA-220SSJ Explanation of Code in Remarks Column Sample Parts ListDCA-220SSJ Suggested Spare Parts Part number on this Suggested Spare Parts listDCA-220SSJ Generator Assy 0601842334 C11100000020601823282 0018205020DCA-220SSJ Generator ASSY. 10A 0042610000 001211006510B 0041210000 0017112045DCA-220SSJ- Control Panel Assy M4223000404 M42230003030222100100 0222100165DCA-220SSJ- Control BOX Assy DCA-220SSJ- Control BOX Assy DCA-220SSJ- Control BOX ASSY. 0601802218 002710602039A 0601806653 39B 0601802149DCA-220SSJ- Engine and Radiator Assy 0602041292 M4923200034RE504836 060204259684 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 M4493601204 M4310301203M4310300903 M431030100386 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 0269200660 06020210700802081003 0602010900DCA-220SSJ- Outputterminal Assy M9220100304 M42307000030801830804 0039316000DCA-220SSJ- Battery Assy C9109100604 01686145510805000904 0805002904DCA-220SSJ- Muffler Assy M4333000303 M43301006020602325066 M4333200004DCA-220SSJ- Fueltank Assy 0845500104 C13630014030810105400 0605501092Enclosure Assy DCA-220SSJ- Enclosure AssyM1413400404 C14130044020019208020 M4423000302Enclosure ASSY. DCA-220SSJ- Enclosure ASSY.M4443200403 0207306000M4443600004 28A 0041206000100 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 51A M4493403804 M4453001203M4453001303 52A M4493403904DCA-220SSJ- Rubber Seals Assy 0228900945 02292012400228901200 0228901260DCA-220SSJ- Nameplate and Decals Assy B9521100404 M4550000303C9521100003 C1550000102106 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 Wilmington Ave Carson, CA Heres HOW to GET Help
Related manuals
Manual 108 pages 30.87 Kb