DCA-220SSJ — GENERATOR OUTPUTS/ GAUGE READING
Maximum Amps
Table 10 shows the maximum amps the generator can pro- vide. DO NOT exceed the maximum amps as listed.
Table 10. Generator Maximum Amps
Model | DCA220SSJ | |
|
| |
Rated Voltage | Maximum Amps | |
|
| |
Single Phase | 488.9 amps (4 wire) | |
120 Volt | ||
| ||
|
| |
Single Phase | 244.4 amps (4 wire) | |
240 Volt | ||
| ||
|
| |
Three Phase | 529 amps | |
240 Volt | ||
| ||
|
| |
Three Phase | 264 amps | |
480 Volt | ||
| ||
|
|
How to Read the Output Terminal Gauge.
The AC ammeter and AC voltmeter
When the voltage
Figure 17. AC Voltmeter | Figure 18. AC Voltmeter Gauge |
(Volt reading on |
Figure 19. AC Ammeter | Figure 20. AC Ammeter |
(Amp reading on U lug) |
The ammeter gauge will only
NOTEshow a reading when the Output Terminal Lugs are connected to a load and in use.