DCA-220SSJ — GENERATOR START-UP PROCEDURE (AUTO MODE)
WARNING - AUTO MODE MAINTENANCE
When running the generator in the AUTO mode, remember the generator can start up at any time without warning. NEVER attempt to perform any maintenance when the generator is in the auto mode.
CAUTION - ENGINE SPEED SWITCH
The Engine Speed Switch must be set to the “High” position when running in the
When starting generator in AUTO mode use the "Manual
1.Perform steps 1 through 6 in the Before Starting section as outlined in the Manual Starting Procedure.
2.Place the engine speed switch (Figure 54) in the HIGH position
Figure 54. Engine Speed Switch (High)
3.Place the MPEC Control Switch (Figure 55) in the AUTO position
When the MPECControlSwitch
is placed in the AUTO position,
NOTE the engine glow plugs will be warmed and the engine will start automatically.
Figure 55. MPEC Control Switch (AUTO)
4.Continue operating the generator as s outlined in the Manual