Multiquip DCA-220SSJ Output Terminal Panel Connections, Uvwo Terminal Output Voltages

Page 46

DCA-220SSJ — OUTPUT TERMINAL PANEL CONNECTIONS

UVWO Terminal Output Voltages

Various output voltages can be obtained using the UVWO output terminal lugs. The voltages at the terminals are de- pendent on the placement of the jumpers plates (6) on the Voltage Change-Over Board and the adjustment of the Voltage Regulator Control Knob.

Remember the voltage change-over board determines the range of the output voltage and can be configured in two different positions that provide 6 different output voltages at the UVWO output terminals. The generator is shipped from the factory in the 240V configuration. The voltage regulator (VR) allows the user to increase or decrease the selected voltage.

3Ø-240V UVWO Terminal Output Voltages

1.Jumper the voltage change-over board for 240V operation as shown in Figure 21.

Figure 23. Voltage Regulator Knob

1Ø-240V UVWO Terminal Output Voltages

1.Make sure the voltage change-over board is jumpered for 240V operation as shown in Figure 21 .

2.Connect the load wires to the UVWO terminals as shown in Figure 24.

 

Figure 24. UVWO Terminal Lugs

 

1Ø-240V Connections

Figure 21. Voltage Change-Over Board

 

240V Configuration

1Ø-139V UVWO Terminal Output Voltages

2.Connect the load wires to the UVWO terminals as shown in Figure 22.

1.Make sure the voltage change-over board is jumpered for 240V operation as shown in Figure 21.

2.Connect the load wires to the UVWO terminals as shown in Figure 25.

Figure 22. UVWO Terminal Lugs

3Ø-240V Connections

3.Turn the voltage regulator knob (Figure 23) clockwise to increase voltage output, turn counterclockwise to decrease voltage output. Use voltage regulator adjustment knob whenever fine tuning of the output voltage is required

Figure 25. UVWO Terminal Lugs

1Ø-139V Connections

PAGE 46 — DCA-220SSJ— OPERATION AND PARTS MANUAL — REV. #1 (03/22/07)

Image 46
Contents Parts List NO. C1870300404 Model DCA-220SSJ2 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 Table of Contents Parts Ordering Procedures When ordering parts Please supply the following informationDCA-220SSJ Specifications DCA-220SSJ Dimensions TOP, Side and Front DimensionsDCA-220SSJ Safety Message Alert Symbols Hazard SymbolsDCA-220SSJ Safety Message Alert Symbols This generator, other property, orGeneral Safety DCA-220SSJ Rules for Safe OperationDCA-220SSJ Rules for Safe Operation Electrical SafetyGenerator Grounding Maintenance Safety Battery SafetyTowing &Transporting Safety EmergenciesDCA-220SSJ Generator Decals DCA-220SSJ Generator Decals Generator Decals Cont inuedDCA-220SSJ Installation Typical Generator Grounding ApplicationWhen connecting the generator Outdoor InstallationIndoor Installation MountingGenerator Control Panel GeneratorEngine Operating Panel Output Terminal PanelDCA-220SSJ Major Components Major ComponentsMenu Button Press this button to enter or exit menu screens Display ParametersMain Menu Navigation DCA-220SSJ Diagnostic DisplayFirst Time Start Up Selecting a LanguageEngine Configuration Data Diagnostic CodeStored Fault Codes To make a selectionDCA-220SSJ Diagnostic Display 24 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 Auxiliary Gage Fault Display will return to the single or four parameter screenActive Fault Codes Code from an engine control unit the single or four Backlight AdjustmentShut Down Codes DamageIntensity Contrast AdjustmentIs highlighted Setup 1- Up Display Select UnitsSetup menu Once the Setup 1-up Display menu icon has beenUp display function Automatic Scan on Setup 4-Up Display Select the 4-Up Custom Setup from the 4-Up Setup menuUtilities information and troubleshooting Version currently in the diagnostic display When the gage data has cleared, the displayGage Data is selected the PowerView will Half duplexMenu Touch the Menu button again to return to the MainTouch the Menu Button Highlight it, then touch Enter ECU did not respond to the PowerView request DCA-220SSJ Diagnostic DisplayGlossary Troubleshooting information No parameter selected for this 4- UP quadrantDCA-220SSJ Generator Control Panel DCA-220SSJ Engine Operating Panel Fuel Gauge Indicates amount of diesel fuel availableDCA-220SSJ Engine Operating Panel Auto On/Off Engine Controller MpecDCA-220SSJ Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-220SSJ Output Terminal Panel Familiarization 100VAC Gfci ReceptaclesConnecting Loads Over Current RelayDCA-220SSJ Load Application Single Phase LoadThree Phase Load Motors and motor-drivenDCA-220SSJ Generator Outputs Maximum Amps How to Read the Output Terminal GaugeDCA-220SSJ Generator OUTPUTS/ Gauge Reading Ammeter gauge will only3Ø-240V Uvwo Terminal Output Voltages DCA-220SSJ Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages DCA-220SSJ Output Terminal Panel Connections3Ø-480V Uvwo Terminal Output Voltages 1Ø-277V Uvwo Terminal Output VoltagesLubrication Oil DCA-220SSJ PRE-SETUPCircuit Breakers Fuel CheckRefueling Procedure RefuelingCoolant Antifreeze Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation FreezingWeatherWiring BatteryBattery Cable Installation AlternatorBefore Starting DCA-220SSJ Generator START-UP Procedure ManualPlace the engine speed switch in the LOW down position Engines exhaust contains harmful emissionsEngine Speed Switch High No Load Starting Auto ModeWhen the generator is set Auto mode, the generator will Tachometer GaugePlace the engine speed switch in the High position Place the Mpec Control Switch in the Auto positionNormal Shutdown Procedure DCA-220SSJ Generator SHUT-DOWN ProceduresEmergency Shutdown Procedure DCA-220SSJ Maintenance Engine Check Oil Level Cleaning the Fuel StrainerAir Removal Replacing Oil FilterDCA-220SSJ Maintenance HEATER/CHARGER To ensure adequate startingDCA-220SSJ Maintenance Trailer Trailer MaintenanceBrakes DCA-220SSJ Maintenance TrailerBrake Adjustment Check the wheel and drum for free rotationTireWear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements DCA-220SSJ Maintenance TrailerStart all wheel lug nuts by hand DCA-220SSJ -TRAILERWIRING Diagram DCA-220SSJ Generatorwiring Diagram Generator Wiring DiagramDCA-220SSJ Enginewiring Diagram Engine Wiring DiagramDCA-220SSJ -TROUBLESHOOTING Generator Generator TroubleshootingDCA-220SSJ -TROUBLESHOOTING Engine Controller Engine Controller Troubleshooting MpecDCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 Sample Parts List DCA-220SSJ Explanation of Code in Remarks ColumnPart number on this Suggested Spare Parts list DCA-220SSJ Suggested Spare PartsDCA-220SSJ Generator Assy 0601823282 C11100000020601842334 0018205020DCA-220SSJ Generator ASSY. 10B 0041210000 001211006510A 0042610000 0017112045DCA-220SSJ- Control Panel Assy 0222100100 M4223000303M4223000404 0222100165DCA-220SSJ- Control BOX Assy DCA-220SSJ- Control BOX Assy DCA-220SSJ- Control BOX ASSY. 39A 0601806653 00271060200601802218 39B 0601802149DCA-220SSJ- Engine and Radiator Assy RE504836 M49232000340602041292 060204259684 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 M4310300903 M4310301203M4493601204 M431030100386 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 0802081003 06020210700269200660 0602010900DCA-220SSJ- Outputterminal Assy 0801830804 M4230700003M9220100304 0039316000DCA-220SSJ- Battery Assy 0805000904 0168614551C9109100604 0805002904DCA-220SSJ- Muffler Assy 0602325066 M4330100602M4333000303 M4333200004DCA-220SSJ- Fueltank Assy 0810105400 C13630014030845500104 0605501092DCA-220SSJ- Enclosure Assy Enclosure Assy0019208020 C1413004402M1413400404 M4423000302DCA-220SSJ- Enclosure ASSY. Enclosure ASSY.M4443600004 0207306000M4443200403 28A 0041206000100 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 M4453001303 M445300120351A M4493403804 52A M4493403904DCA-220SSJ- Rubber Seals Assy 0228901200 02292012400228900945 0228901260DCA-220SSJ- Nameplate and Decals Assy C9521100003 M4550000303B9521100404 C1550000102106 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 DCA-220SSJ- Operation and Parts Manual REV. #1 03/22/07 Heres HOW to GET Help Wilmington Ave Carson, CA
Related manuals
Manual 108 pages 30.87 Kb

DCA-220SSJ specifications

The Multiquip DCA-220SSJ is a high-performance diesel generator renowned for its reliability and efficiency in various applications. Whether in construction, events, or emergency backup, this generator is designed to provide dependable power when you need it most.

One of the main features of the DCA-220SSJ is its powerful 220 kVA output capability. With a robust engine, this generator can support a wide range of equipment, making it suitable for both heavy-duty industrial tasks and lighter applications. It is equipped with a 4-cylinder, liquid-cooled diesel engine, known for its durability and consistent performance. The engine technology used in the DCA-220SSJ ensures low fuel consumption while minimizing emissions, adhering to stringent environmental regulations.

The DCA-220SSJ also features a compact design, making it easy to transport and set up in various locations. Its sturdy skid-mounted frame provides stability and protection to the internal components, while the weather-resistant canopy ensures that it can operate reliably in diverse weather conditions. This design is particularly beneficial for outdoor applications where exposure to the elements is a concern.

An important aspect of the DCA-220SSJ's functionality is its advanced control panel. It includes digital monitoring systems that provide real-time data on performance metrics such as voltage, frequency, and operating hours. This information helps users maintain the generator effectively and plan for servicing to avoid unexpected downtime. The generator also features automatic voltage regulation (AVR), which maintains a stable output voltage, protecting connected equipment from power surges.

Safety is a top priority with the DCA-220SSJ, which includes several built-in safety features. These include low oil pressure shutdown, high-temperature shutdown, and overload protection, ensuring that the generator operates safely under all conditions.

Furthermore, the generator is designed for ease of maintenance, with accessible service points to streamline regular checks and repairs. This helps to extend the lifespan of the unit and ensures reliable operation over time.

In summary, the Multiquip DCA-220SSJ is a versatile and robust diesel generator. With its powerful output, advanced technologies, user-friendly controls, and a strong focus on safety and efficiency, it stands out as an essential tool for various industries needing reliable power solutions.