Homelite UT902211 manuel dutilisation Important Safety Instructions, English

Page 7

IMPORTANT SAFETY INSTRUCTIONS

DANGER:

Carbon Monoxide. Using a generator indoors CAN KILL YOU IN MINUTES.

Generator exhaust contains high levels of carbon mon- oxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even if you cannot smell the exhaust, you could be breathing CO.

Never use a generator inside homes, garages, crawl spaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Us- ing a fan or opening windows and doors does NOT supply enough fresh air.

ONLY use a generator outdoors and far away from open windows, doors, and vents. These openings can pull in generator exhaust.

Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-backup CO alarm in the home.

If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning.

WARNING:

Read and understand all instructions. Failure to follow all instructions listed below may result in electrocution, fire, and/or carbon monoxide poisoning, which will cause death or serious injury.

WARNING:

National Electric Code requires generator to be grounded to an approved earth ground. Before using the ground ter- minal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or or- dinances that apply to the intended use of the generator­.

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be followed during installation and maintenance of the genera- tor and batteries.

Do not connect to a building’s electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician.

Do not allow children or untrained individuals to use this unit.

Never start or run the engine inside a closed or partially enclosed area. Breathing exhaust fumes will kill you.

Keep all bystanders, children, and pets at least 10 feet away.

Wear sturdy and dry shoes or boots. Do not operate while barefoot.

Do not operate generator when you are tired or under the influence of drugs, alcohol, or medication.

Keep all parts of your body away from any moving parts and all hot surfaces of the unit.

Do not touch bare wire or receptacles.

Do not use generator with electrical cords which are worn, frayed, bare, or otherwise damaged.

Before storing, allow the engine to cool and drain fuel from the unit.

Do not operate or store the generator in rain, snow, or wet weather.

Store the generator in a well-ventilated area with the fuel

tank empty. Fuel should not be stored near the generator­ .

Empty fuel tank, close fuel valve, and restrain the unit from moving before transporting in a vehicle.

Allow engine to cool for five minutes before refueling.

To reduce the risk of fire and burn injury, handle fuel with care. It is highly flammable.

Do not smoke while handling fuel.

Store fuel in a container approved for gasoline.

Position the unit on level ground, stop engine, and allow to cool before refueling.

Loosen fuel cap slowly to release pressure and to keep fuel from escaping around the cap.

Tighten the fuel cap securely after refueling.

Wipe spilled fuel from the unit.

Never attempt to burn off spilled fuel under any circum- stances.

Generators vibrate in normal use. During and after the use of the generator, inspect the generator as well as extension cords and power supply cords connected to it for damage resulting from vibration. Have damaged items repaired or replaced as necessary. Do not use plugs or cords that show signs of damage such as broken or cracked insulation or damaged blades.

For power outages, permanently installed stationary gen- erators are better suited for providing back-up power to the home. Even a properly connected portable generator can become overloaded. This may result in overheating or stressing the generator components, possibly leading to generator failure.

Use only authorized replacement parts and accessories and follow instructions in the section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of shock or injury.

Page 3 — English

Image 7
Contents Save this Manual for Future Reference Watt GeneratorNeutral Bonded to Frame Page CM G Lanyard bracelet, correa AC DOFF Introduction Table of Contents3 English Important Safety Instructions4 English Specific Safety Rules5 English SymbolsSymbol Name DESIGNATION/EXPLANATION Symbol Signal MeaningName DESIGNATION/EXPLANATION Safety Labels6 English HOT Surface Warning Fuel WarningEngine Lubricant Warning Grounding WarningElectric Motor Loads Ground Fault Circuit InterrupterElectrical Extension Cord Cable SizeGenerator Capacity Power Management9 English Features Assembly CHECKING/ADDING Lubricant OperationApplications Before Operating the UnitStopping the Engine Using Fuel StabilizerOxygenated Fuels Starting the EngineSpark Plug Maintenance MaintenanceGeneral Maintenance CHECKING/CLEANING AIR FilterTransporting Cleaning the Exhaust Port and MufflerSpark Arrestor Emptying Fuel TANK/CARBURETOR16 English Maintenance ScheduleStorage Storage Time Prior to StoringProblem Possible Cause Solution Troubleshooting17 English Save Your Sales Slip WarrantyWarranty Coverage HOW to Obtain Warranty ServiceWarranty Periods Limited Engine Warranty19 English 20 English Your Warranty Rights and Obligations2 Français Table DES MatièresMise À LA Terre DU Générateur Arrière3 Français Instructions Importantes Concernant LA SécuritéAvertissement Conserver CES Instructions4 Français Règles DE Sécurité Particulières5 Français SymbolesSymbole NOM Désignation / Explication Symbole Signal SignificationNOM Désignation / Explication Autocollants DE Sécurité6 Français Avertissement Concernant LES Surfaces Brûlantes Avertissement Concernant LE CarburantAvertissement Concernant LE Lubrifiant Moteur Mise À LA Terre AvertissementCharges DU Moteur Électrique Caractéristiques ÉlectriquesDisjoncteur DE Fuite À LA Terre Taille DU Câble DU Cordon ProlongateurGestion DE L’ÉNERGIE Capacité DU Générateur9 Français Caractéristiques Outils Nécessaires Installation DES Roues’INSTALLATION DE LA Poignée Assemblage12 Français UtilisationAvant D’UTILISER L’UNITÉ VÉRIFICATION/AJOUT DE LubrifiantMise EN Marche DU Moteur VÉRIFICATION/AJOUT DE CarburantUtilisation DE Stabilisateur DE Carburant Carburants OxygénésVidange DE LE Lubrifiant Moteur EntretienEntretien Général INSPECTION/NETTOYAGE DU Filtre À AIRTransport Nettoyage DE L’ORIFICE D’ÉCHAPPEMENT ET DU SilencieuxPARE-ÉTINCELLES Vidange DU Réservoir DE CARBURANT/ Carburateur16 Français RemisageCalendrier D’ENTRETIEN Durée DU Remisage Avant LE RemisageDépannage Problème Cause Possible Solution17 Français Comment Bénéficier D’UN Entretien Sous Garantie GarantieCouverture DE LA Garantie Conserver LES FacturesPériodes DE GARANTIE  Garantie Limitée DE Moteur19 Français VOS Droits ET Obligations Dans LE Cadre DE LA Garantie 20 FrançaisPág. posterior Índice DE ContenidoIntroducción Peligro Conexión a Tierra DEL GeneradorGuarde Estas Instrucciones Instrucciones DE Seguridad ImportantesPeligro AdvertenciaPágina 4 Español Reglas DE Seguridad EspecíficasSímbolo Señal Significado SímbolosPrecaución Símbolo Nombre Denominación / ExplicaciónNombre Denominación / Explicación Etiquetas DE SeguridadPágina 6 Español Advertencia DE Superficie Caliente Advertencia DE CombustibleAdvertencia DEL Lubricante DE Motor Advertencia Acerca DE LA Conexión a TierraPrecaución Aspectos EléctricosCargas DE Motores Eléctricos Calibre DEL Cordón DE ExtensiónCapacidad DEL Generador Administración DE LA PotenciaPágina 9 Español Características Armado Verificación Y Abastecimiento DE Lubricante FuncionamientoAplicaciones Antes DE Accionar LA UnidadArranque DEL Motor Verificación Y Abastecimiento DE CombustibleUSO DE Estabililzador DE Combustible Combustibles OxigenadosCambio DEL Lubricante DEL Motor MantenimientoMantenimiento General Revisión Y Limpieza DEL Filtro DE AireTransporte Limpieza DEL Orificio DE Escape Y DEL SilenciadorParachispas Vaciar DEL Tanque DEL Combustible Y DEL CarburadorPrograma DE Mantenimiento AlmacenamientoPágina 16 Español Problema Causa Posible Solución Corrección DE ProblemasPágina 17 Español Exclusiones Y Limitaciones GarantíaCobertura DE LA Garantía Guarde SU Comprobante DE CompraPlazos DE Garantía Garantía Limitada DE MotorPágina 20 Español Garantía/ Página AVERTISSEMENT  OPERATOR’S ManualManuel D’UTILISATION Manual DEL Operador