MAINTENANCE
STORAGE
When preparing the generator for storage, allow the unit to cool completely then follow the guidelines below.
STORAGE TIME | PRIOR TO STORING |
|
|
Less than 2 months | Run the generator until the fuel tank is empty. |
|
|
2 months to 1 year | Start and run the engine for at least 5 minutes to allow stabilizer to treat the entire fuel system. |
| Run the generator until the fuel tank is empty. |
|
|
1 year or more | Start and run the engine for at least 5 minutes to allow stabilizer to treat the entire fuel system. |
| Remove spark plug. |
| Run the generator until the fuel tank is empty. |
| Put a tablespoon of engine oil into the spark plug cylinder. Turn the engine slowly with the pull |
| rope to distribute the oil. |
| Reinstall spark plug. |
| Change engine lubricant. |
| After removal from storage: |
| Fill with fresh gasoline. |
|
|
MAINTENANCE SCHEDULE
| Before | After 1st month | Every 3 months | Every 6 months | Every year or |
| or 20 hours of | or 50 hours of | or 100 hours | after 300 hours | |
| each use | ||||
| operation | operation | of operation | of operation | |
|
| ||||
|
|
|
|
|
|
Check Engine Lubricant | |
|
|
|
|
|
|
|
|
|
|
Change Engine Lubricant |
| |
| |
|
|
|
|
|
|
|
Check Air Filter | |
|
|
|
|
|
|
|
|
|
|
Clean Air Filter |
|
| |
|
|
|
|
|
|
|
|
Change Air Filter |
|
|
|
| |
|
|
|
|
|
|
Check/Adjust Spark Plug |
|
|
| |
|
|
|
|
|
|
|
Replace Spark Plug |
|
|
|
| |
Check/Adjust Idle Speed |
|
|
|
| |
|
|
|
|
|
|
Check/Adjust Valve |
|
|
|
| |
Clearance* |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
Clean Fuel Tank and |
|
|
| |
|
Filter* |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
Check Fuel Tube |
|
|
|
| |
|
|
|
|
|
|
* These items should only be carried out by an authorized service center.
NOTE: Maintenance should be performed more frequently when generator is used in dusty areas.
When generator has exceeded the maximum figures specified in the table, maintenance should still be cycled according to the intervals of time or hours stated herein.