Section 7 - Exploded Views and Parts

 

 

 

 

 

 

 

 

 

 

 

 

40kW Liquid-cooled Generators

 

 

 

 

Enclosure — Drawing No. 0F4930-C

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

1

0E8418

1

DUCT INTAKE MID AL

 

2

0E8414

1

DUCT DISCHARGE RH AL

 

3

0E8413

1

DUCT DISCHARGE LH AL

 

4

0C2454

62

SCREW TH-FRM M6-1 X 16 N WA Z/JS

 

5

0E7807

1

BAFFLE REAR BOTTOM

 

6

0E5902

1

POST CORNER LH REAR HSB AL

 

7

0E5903

1

POST CORNER RH REAR HSB AL

 

8

0E8387

1

BAFFLE REAR TOP

 

9

0E5912

2

DOOR SIDE HSB AL

 

10

0F5570

1

SUPPORT RH SIDE HSB AL

 

11

089961

2

FOAM STRIP 3/4” WIDE X 3/16” THK (40” LG)

 

12

0A2115

4

WASHER NYLON .257

 

13

0E8404

1

BRACKET STIFFENER RH FRONT

 

14

0D2538A

1

HINGE LIFT OFF TYPE B KNUCKLE

 

15

0D2538

1

HINGE LIFT OFF TYPE B PIN

 

16

078115

8

WASHER SELF LOCKING DOME

 

17

022097

12

WASHER LOCK M6-1/4

 

18

022473

12

WASHER FLAT 1/4-M6 ZINC

 

19

0E7570

2

GAS SPRING

 

20

0E7571

4

BALL STUD GAS SPRING MOUNT

 

21

070015

4

NUT HEX 5/16-18 LOCK

 

22

0E7662

4

SCREW WING M6-1.00 X 25

 

23

0D2537A

1

HINGE LIFT OFF TYPE A KNUCKLE

 

24

0D2537

1

HINGE LIFT OFF TYPE A PIN

 

25

0D2023

2

TRIM VINYL SELF GRIPPING (91” LG)

 

26

0E7869

2

BRACKET STIFFENING BACK

 

27

0E8001

1

MUFFLER BOX

 

28

0F5568

1

ROOF HSB AL ACOUSTIC

 

29

0E8798

1

BRACE, FRONT TOP

 

30

0D3037A

1

LATCH 1/4 TURN NONLOCKING

 

31

0C7781

2

PAWL DOOR HSB

 

32

0E5910

1

SUPPORT LH SIDE HSB AL

 

33

0E8052

1

MUFFLER BOX TOP

 

34

0D3037

1

LATCH QUARTER TURN LOCKING

 

35

0E5900

1

POST CORNER LH FRONT HSB AL

 

36

0E5901

1

POST CORNER RH FRONT HSB AL

 

37

0F4938A

1

BRACE FRONT BOTTOM

 

38

0E8415

1

DUCT DISCHARGE MID AL

 

39

026850

4

WASHER SHAKEPROOF EXT 1/4 STL

 

40

0912970063

2

ASSY WIRE 14AWG 7.5 #0 GRN/YEL

 

41

0912970064

2

ASSY WIRE 14AWG 7.5 #0 GRN/YEL

 

42

049813

2

NUT HEX M6 X 1.0 G8 YEL CHR

 

43

0E8416

1

DUCT INTAKE LH AL

 

44

0E8417

1

DUCT INTAKE RH AL

 

45

0E8665

1

BRACKET STIFFENER LH FRONT

 

46

0D2023

1

TRIM VINYL SELF GRIPPING (165.5” LG)

 

47

0E7829N

2

AI ROOF PANEL 2

 

48

0E7829T

1

AI SUPPORT RH PANEL

 

49

0E7829S

1

AI SUPPORT LH PANEL

 

50 *

0E8442

1

KIT INSULATION 3.9L HSB

 

51

0E7829A

1

AI ROOF PANEL 1

 

52

0E7829B

2

AI DOOR PANEL

 

53

0E7829P

4

AI CORNER POST PANEL 1

 

54

0E7829R

2

AI CORNER POST PANEL 2

 

55

043116

8

SCREW HHC M6-1.0 X 12 G8.8

* ALL ITEMS NOTATED WITH “AI” ARE COMPONENTS OF 0E8442

31

Image 33
Contents Liquid-cooled, Prepackaged Standby Generators ‹ Operation and Maintenance Authorized Service Dealer Location‹ HOW to Obtain Service IntroductionTable of Contents  Warning   Electrical Hazards  Generator Transfer SwitchAutomatic System Operation Generator AC Connection Systems‹ 1.7.2 High Coolant Temperature Switch ‹ 1.7.1 LOW OIL Pressure SwitchGenerator Fuel System Engine Protective DevicesUnpacking Reconfiguring the Fuel System SpecificationsLifting the Generator Fuel ConsumptionBefore Installation Torque SpecificationsStandby Generator Installation Coolant RecommendationsGenerator Mounting Support Generator Location‹ 2.1.1 Nfpa Standards ‹ 2.1.2 Other Published StandardsTotal Circuit Isolation Method Basic Standby Electric SystemEmergency Circuit Isolation Method Grounding the GeneratorTransfer Switch Signal Connections Battery InstallationGenerator AC Neutral Connections Preparation Before START-UP ‹ 3.2.1 AUTO/OFF/MANUAL Switch Using AN Engineered GTS Transfer Switch‹ 3.2.2 Fault Indicator LED Control Console Components‹ 3.2.5 SET Exercise Time Switch Engine Governor AdjustmentsManual Transfer START-UP ‹ 3.2.6 System Ready LEDRetransfer and Shutdown Automatic OperationWeekly Exercise Cycle Overload Protection for Engine DC Electrical System Checking Fluid LevelsCooling System ‹ 4.5.1 Check Engine OIL Level ‹ 4.5.2 Check Battery‹ 4.5.3 Exercise System ‹ 4.5.4 Inspect Cooling System‹ 4.5.11 Changing the Engine AIR Cleaner Miscellaneous Maintenance‹ 4.6.1 Cleaning the Generator ‹ 4.5.13 Coolant Change‹ 4.6.4 Battery Replacement ‹ 4.6.3 Battery MaintenanceService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsElectrical Data Electrical Data Electrical Data Electrical Data Engine Block Hold Down Battery Assy WireBOOT, Contactor Cables Battery Post Covwer BlackDetail Duct Intake MID AL Assy Wire 14AWG 7.5 #0 GRN/YELDuct Discharge RH AL Duct Discharge LH ALPage Control BOX HSB Assy 2A 12V UL BatteryDecal AVR Cover Cover Front Panel HSBComes with Engine Assembly Resistor Cover Flywheel Access CountersunkFlexplate 3.9L HSB Plug STD Pipe 3/8To a 17 Radiator Copper Brass Tank Coolant RecoveryVENTURI,3.9L Cryslr HSB 22FAN Radiator Support L/H SideTo Engine Hold Down AIR Cleaner Base AIR Cleaner PlatePlate AIR Cleaner TOP Flange Fuel InletLocktight Rotor 390 20KW 1P Direct HSB 2.5L Ford Rotor 390 15KW 1P Direct HSB 2.5L FordRotor 390 25KW 1P Direct HSB 2.5L Ford Rotor 39030AD1 HSB TecumExhaust Flange 2 Pipe NUT TOP Lock FL M12-1.75Washer Lock M12 Exhaust Blanket 800MMInstallation Diagram 40kW Liquid-cooled Generators 40kW Liquid-cooled Generators This Warranty Shall not Apply to the Following

005012-1 specifications

Generac Power Systems 005012-1 is a high-performance generator designed to provide reliable backup power for homes and businesses. Known for its innovative features and advanced technology, this generator is engineered to ensure consistent performance during power outages.

At the heart of the 005012-1 is its robust engine. With a Generac 999cc V-Twin OHV engine, it delivers impressive power output and durability. This engine is designed to run efficiently, making the generator an optimal choice for extended use during outages. The Quiet Test feature allows the generator to run at a lower volume during self-diagnostic tests, ensuring minimal disturbance to its surroundings.

One of the standout features of the 005012-1 is its ability to automatically detect power loss and start up within seconds. This automatic transfer switch ensures that when the primary power source fails, the generator takes over seamlessly, keeping essential appliances and systems operational. This rapid response time is crucial for maintaining comfort and safety during outages.

The generator is equipped with a user-friendly control panel that includes an LCD display. This panel provides real-time information about power usage, operational status, and maintenance reminders, enabling users to stay informed and address any issues promptly. Additionally, the model offers flexible monitoring options through mobile connectivity, allowing users to check the generator's status remotely via smartphone or other devices.

Designed for longevity, the 005012-1 features a durable aluminum enclosure that protects the generator from the elements, ensuring reliable operation in various conditions. Its compact design allows for easy installation and integration into existing power systems without occupying excessive space.

Fuel efficiency is another hallmark of the 005012-1, as it operates on propane or natural gas, providing flexibility in fuel choice. This versatility not only aids in reducing operational costs but also appeals to environmentally conscious users seeking cleaner energy solutions.

Overall, Generac Power Systems 005012-1 stands out as a dependable and technologically advanced generator, combining power, efficiency, and user-friendly features. Its commitment to reliability makes it a top choice for those looking to safeguard their homes and businesses against unexpected power interruptions.