e)Check that the PTO is disengaged.
f)Check that the spark plug wires are properly connected.
g)Check for loose or faulty wiring connections.
h)Check for corrosion at all wiring connections. Even minor corrosion may cause a faulty connection. Clean connector terminals thoroughly with electrical contact cleaner, apply dielectric grease and reconnect.
NOTE: When disconnecting electrical connectors DO NOT pull on the wires to separate the connectors.
NOTE: After carefully checking the above steps, attempt to start the engine. If it does not start, contact your authorized Exmark service dealer.
IMPORTANT: It is essential that all operator safety mechanisms be connected and in proper operating condition prior to mower use.
When a problem occurs, do not overlook the simple causes. For example: starting problems could be caused by an empty fuel tank.
The following table lists some of the common causes of trouble. Do not attempt to service or replace major items or any items that call for special timing of adjustments procedures (such as valves, governor, etc.). Have this work done by your Engine Service Dealer.
ENGINE TROUBLESHOOTING TABLE
PROBLEM | NO | IMPROPER | DIRT IN | DIRTY AIR | FAULTY | ENGINE | BLOCKED | INCORRECT | DIRTY | INSUFFICIENT | |
SPARK | FUEL | OIL | AIR | BATTERY | |||||||
FUEL | FUEL | FUEL LINE | FILTER | OVERLOADED | |||||||
|
|
|
|
| PLUG |
| FILTER | LEVEL | SCREEN | CHARGE | |
Will not start | X |
| X | X | X | X | X |
|
| X | |
Hard starting | X | X | X | X | X | X | X |
|
|
| |
Stops suddenly | X |
| X | X |
| X | X | X | X |
| |
Lacks power |
| X | X | X | X | X | X | X | X |
| |
Operates erratically |
| X | X | X | X | X | X |
| X |
| |
Knocks or pings |
| X |
|
|
| X |
|
| X |
| |
Skips or misfires |
| X | X | X | X |
|
|
| X |
| |
Backfires |
|
| X | X | X | X |
|
| X |
| |
Overheats* |
|
| X | X |
| X |
| X | X |
| |
High fuel consumption |
|
|
| X | X | X |
|
| X |
| |
|
|
|
|
|
|
|
|
|
|
|
- 41 -