Technical Reference
&Dn Controls Data Terminal Ready (DTR) operations
&D0 | DTR override |
&D1 | DTR toggle causes online Command mode |
&D2 | Normal DTR operations |
&D3 | Resets on receipt of DTR |
&Fn Loads a read-only (non-programmable) factory configuration
&F0 | Generic template |
&F1 | Hardware flow control template |
&F2 | Software flow control template |
&Gn Sets Guard Tone | |
&G0 | No guard tone, U.S. and Canada |
&G1 | 550 Hz guard tone, some European countries, requires |
| B0 setting |
&G2 | 1800 Hz guard tone, U.K., requires B0 setting |
&Hn Sets Transmit Data (TD) flow control (see also &Rn)
&H0 | Flow control disabled |
&H1 | Hardware flow control, Clear to Send (CTS) |
&H2 | Software flow control, XON/XOFF |
&H3 | Hardware and software flow control |
&In Sets Receive Data (RD) software flow control (see also &Rn)
&I0 | Software flow control disabled |
&I1 | XON/XOFF signals to your modem and remote system |
&I2 | XON/XOFF signals to your modem only |
&Kn Enables/disables data compression
&K0 | Data compression disabled |
&K1 | Auto enable/disable |
&K2 | Data compression enabled |
&K3 | MNP5 compression disabled |
&Mn Sets Error Control (ARQ) for connections at 1200 bps and
higher |
|
&M0 | Normal mode, error control disabled |
&M1 | Reserved |
&M2 | Reserved |
&M3 | Reserved |
&M4 | Normal/ARQ |
&M5 | ARQ mode |
59