2 INSTALLING THE OUTDOOR BRIDGE

This equipment must be installed in compliance with local and national building codes, regulatory restrictions, and FCC rules. For the safety of people and equipment, only professional network personnel should install the bridge, cables, and antennas.

CAUTION: Before installing, see the important warnings and cautions in “Safety Information” on page 13.

INSTALLATION REQUIREMENTS

The following items are required for installation:

For a point-to point configuration, two 3Com outdoor bridges.

For a point-to-multipoint configuration, one 3Com 11Mbps Wireless LAN Access Point 8000 (or other Wi-Fi compliant access point) with an omnidirectional antenna for one building, and one 3Com outdoor bridge for each other building.

Mounting hardware (supplied with each bridge).

Properly grounded outdoor mast or wall mount.

Lightning arrestor properly grounded at each building in the topology.

Outdoor rated category 5 Ethernet cable (3Com part number 3CWE487 recommended).

POWER REQUIREMENTS

The bridge complies with the IEEE 802.3af power-over-Ethernet standard. It receives power over outdoor rated Ethernet cable (3Com part number 3CWE487 recommended). Installation requires the use of either the 3Com power supply provided or IEEE 802.3af compliant power supply equipment (output power rated 48 V dc @ 200 mA minimum). Such equipment must be safety certified according to UL, CSA, IEC or other applicable national or international safety requirements

10

Page 10