1-10CHAPTER 1: INSTALLING THE HARDWARE

Attaching a

You can attach your SuperStack II bridge/router to a SuperStack II

Redundant Power

Redundant Power System (RPS). You will need to order the connecting

System

cable (part number 3C8101) from 3Com. The following figure shows

 

where to attach this cable.

 

Rear panel of unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attach RPS cable here

For full power supply redundancy, attach one end of the RPS cable to the rear panel on the bridge/router and the other end to the RPS. Then attach one end of the power cord to the rear panel on the bridge/router and the other end to a power outlet.

In this configuration, the internal supply provides power. If the internal supply fails or is switched off, or if there is a power failure, the RPS is activated and the bridge/router reboots.

To reset a bridge/router in this configuration, turn the power off, wait 5 seconds and turn it back on. The bridge/router switches to the RPS, then switches back to the internal supply to reboot.

CAUTION: For system susceptibility protection, always leave the AC cord attached to the bridge/router hardware and to a power outlet.

Internal power supply failure is rare. If it occurs, the power switch on your bridge/router will not operate. To reboot you will need to unplug the RPS cable and then plug it back in. Replace your bridge/router with another bridge/router that has a functioning internal power supply as soon as possible. Contact your 3Com representative to replace your bridge/router.