3Com VFD-D D manual Protection and Special Parameters

Models: VFD-D D

1 141
Download 141 pages 56.51 Kb
Page 38
Image 38

Chapter 4 Parameter SettingsDD Series

06 Protection and Special Parameters

This parameter can be set during operation.

Parameter

Explanation

Settings

Factory

VF

VFP

SVC

FOC

FOC

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06.00

Software Braking Level

350.0~450.0Vdc

380.0

06.01

ED Setting of Brake

0~100%

50

 

Resistor

 

 

 

 

 

 

 

06.02

Current Boundary

0250%

200

 

 

 

06.03

Forward Motor Torque Limit

0250%

200

 

 

 

06.04

Forward Regenerative

0250%

200

 

 

 

 

Torque Limit

 

 

 

 

 

 

 

06.05

Reverse Motor Torque Limit

0250%

200

 

 

 

06.06

Reverse Regenerative

0250%

200

 

 

 

 

Torque Limit

 

 

 

 

 

 

 

06.07

Emergency/Force Stop

0:Coast to stop

3

 

Deceleration Method

1: Decelerate by 1st decel. time

 

 

 

 

 

 

 

 

2: Decelerate by 2nd decel. time

 

 

 

 

 

 

 

 

3:By Pr.05.33 setting

 

 

 

 

 

 

06.08

Low Voltage Level

160.0~270.0Vdc

180.0

06.09

High Temperature

0.0~110.0

85.0

 

Overheat Warning (OH)

 

 

 

 

 

 

 

06.10

Action after door

Bit 0=0:Not detecting incorrect

2

 

re-open/re-close

open/close limit

 

 

 

 

 

 

 

 

Bit 0=1:Detects incorrect open/close

 

 

 

 

 

 

 

 

limit

 

 

 

 

 

 

 

 

Bit 1=0:Door re-open when door close

 

 

 

 

 

 

 

 

error occur

 

 

 

 

 

 

 

 

Bit 1=1:Door will not re-open when door

 

 

 

 

 

 

 

 

close error occur

 

 

 

 

 

 

 

 

Bit 2=0:Enable S-Curve when door

 

 

 

 

 

 

 

 

re-open

 

 

 

 

 

 

 

 

Bit 2=1:Disable S-Curve when door

 

 

 

 

 

 

 

 

re-open

 

 

 

 

 

 

 

 

Bit 3=0: When door open complete, will

 

 

 

 

 

 

 

 

not reset door position to

 

 

 

 

 

 

 

 

100.0%.

 

 

 

 

 

 

 

 

Bit 3=1:When door open complete,

 

 

 

 

 

 

 

 

resets door position to 100.0%

 

 

 

 

 

 

 

 

Bit4=0 Door opening in position not

 

 

 

 

 

 

 

 

supported, limited signal will be

 

 

 

 

 

 

 

 

output after the torque is

 

 

 

 

 

 

 

 

enabled.

 

 

 

 

 

 

 

 

Bit4=1 Door opening in position is

 

 

 

 

 

 

 

 

supported, limited signal will be

 

 

 

 

 

 

 

 

output after the torque is

 

 

 

 

 

 

 

 

enabled.

 

 

 

 

 

 

 

 

Bit5=0 Reset LVn error automatically,

 

 

 

 

 

 

 

 

MO terminal sends error signal

 

 

 

 

 

 

 

 

Bit5=1 Reset LVn error

 

 

 

 

 

 

 

 

automatically, MO terminal

 

 

 

 

 

 

 

 

sends error signal

 

 

 

 

 

 

 

 

4-14

 

 

 

 

 

 

Page 38
Image 38
3Com VFD-D D manual Protection and Special Parameters

VFD-D D specifications

The 3Com VFD-D D is an advanced networking solution designed to meet the demands of modern communication and connectivity. As part of 3Com's extensive portfolio of networking products, this device stands out due to its robust features, innovative technologies, and characteristics that cater to various enterprise environments.

One of the main features of the 3Com VFD-D D is its high-speed data processing capability. Operating at speeds that comfortably support high-bandwidth applications, the device is equipped to handle a multitude of simultaneous connections without compromising performance. This makes it an ideal choice for businesses where consistent, fast access to data is critical.

In terms of connectivity options, the VFD-D D supports a variety of protocols, allowing it to seamlessly integrate with existing infrastructure. Whether through Ethernet, Fiber Channel, or wireless technologies, the device offers versatility in connecting diverse network configurations. This adaptability ensures that organizations can optimize their network setups according to their specific requirements.

The 3Com VFD-D D also boasts advanced security features designed to protect sensitive data from potential threats. With built-in encryption protocols and secure access measures, the device safeguards information while offering administrators full control over user permissions. This heightened security is especially important in today's risk-laden digital landscape, providing peace of mind for organizations entrusting their data to the network.

Moreover, the VFD-D D is designed with scalability in mind. Its modular architecture allows businesses to expand their network capabilities as needed, ensuring that the device can grow alongside their evolving requirements. This flexibility helps organizations manage costs effectively while preparing for future technological advancements.

Another characteristic that sets the 3Com VFD-D D apart is its user-friendly management interface. Administration tasks can be performed quickly and intuitively, reducing the burden on IT staff while enabling efficient network monitoring and troubleshooting. With real-time analytics and reporting capabilities, organizations can gain valuable insights into their network's performance.

Overall, the 3Com VFD-D D combines speed, security, and scalability in a single device, making it a powerful addition to any enterprise network. Its advanced features and technologies are tailored to support the dynamic needs of modern businesses, ensuring reliable performance and robust connectivity in an increasingly interconnected world.