Chapter 4 Parameter SettingsDD Series

10

OD command

Active when the operation direction is door open.

11

CD command

Active when the operation direction is door close.

12

Demo Indication

Active when the drive is in demo mode.

13

Demo complete

Active when each time door open/close is complete in demo

 

mode (contact closed for 0.5s only).

 

 

14

Emergency stop indication

Active when emergency stop is detected.

15

Force stop indication

Active when force stop is detected.

 

 

Active when position mode (Pr.06-11) is set to “no door close

 

Door open complete (limit)

limit signal” and the door width is greater than the setting in

16

Pr.04-06.

signal output

 

Active when position mode (Pr.06-11) is set to door close limit

 

 

 

 

signal allow and one of MI (Pr.02-01~02-05) is set to 14.

 

Door close complete (limit)

Active when position mode (Pr.06-11) is set to “no door close

 

signal output

limit signal” and the door width is less than Pr.05-06 setting

17

 

during the door close.

 

 

Active when position mode (Pr.06-11) is set to door close limit

 

 

signal allow and one of MI (Pr.02-01~02-05) is set to 15.

18

Door close error

Active when door close error. (Includes door reopen and not

 

reopen).

 

 

19

Position complete signal

Active when positioning is completed after drive power is on or

 

PGEr. This function is valid when Pr.00-10=00.

 

 

20

Position Detection 1(for door

Active when door close width is lower than Pr.06-14 (valid when

close only)

door close).

 

21

Position Detection 2(for door

Active when door close width is lower than Pr.06-15 (valid when

close only)

door close).

 

22

Position Detection 3(for door

Active when door close width is lower than Pr.06-16 (valid when

close only))

door close).

 

23

Position Detection 1(for door

Active when door close width is lower than Pr.06-14 (valid when

open only)

door open).

 

24

Position Detection 2(for door

Active when door close width is lower than Pr.06-14 (valid when

open only)

door open).

 

25

Position Detection 3(for door

Active when door close width is lower than Pr.06-14 (valid when

open only)

door open).

 

26

PG feedback error

Active when PG feedback signal error is detected

27

output signal when unable to

 

open the door

 

 

 

28

over torque (OT1)

 

Digital Output Direction

Control mode VF VFPG SVC FOCPG FOCPM

Factory setting: 0

 

Settings 0065535

 

This parameter is set via bit setting. If a bit is 1, the corresponding output acts in the opposite way.

Example:

 

If Pr02-08=1 (operation indication) and Pr.02-13=0, Relay 1 RA-RC is closed when the drive runs and is open when the drive is stopped.

If Pr02-08=1 and Pr02-13=1, Relay 1 RA-RC is open when the drive runs and is closed when the drive is stopped.

Position Detection Signal 1

Control mode VF VFPG SVC FOCPG FOCPM

Factory setting: 25.0

 

Settings 0.0~100.0%

 

Position Detection Signal 2

4-42

Page 66
Image 66
3Com VFD-D D manual Digital Output Direction, Position Detection Signal

VFD-D D specifications

The 3Com VFD-D D is an advanced networking solution designed to meet the demands of modern communication and connectivity. As part of 3Com's extensive portfolio of networking products, this device stands out due to its robust features, innovative technologies, and characteristics that cater to various enterprise environments.

One of the main features of the 3Com VFD-D D is its high-speed data processing capability. Operating at speeds that comfortably support high-bandwidth applications, the device is equipped to handle a multitude of simultaneous connections without compromising performance. This makes it an ideal choice for businesses where consistent, fast access to data is critical.

In terms of connectivity options, the VFD-D D supports a variety of protocols, allowing it to seamlessly integrate with existing infrastructure. Whether through Ethernet, Fiber Channel, or wireless technologies, the device offers versatility in connecting diverse network configurations. This adaptability ensures that organizations can optimize their network setups according to their specific requirements.

The 3Com VFD-D D also boasts advanced security features designed to protect sensitive data from potential threats. With built-in encryption protocols and secure access measures, the device safeguards information while offering administrators full control over user permissions. This heightened security is especially important in today's risk-laden digital landscape, providing peace of mind for organizations entrusting their data to the network.

Moreover, the VFD-D D is designed with scalability in mind. Its modular architecture allows businesses to expand their network capabilities as needed, ensuring that the device can grow alongside their evolving requirements. This flexibility helps organizations manage costs effectively while preparing for future technological advancements.

Another characteristic that sets the 3Com VFD-D D apart is its user-friendly management interface. Administration tasks can be performed quickly and intuitively, reducing the burden on IT staff while enabling efficient network monitoring and troubleshooting. With real-time analytics and reporting capabilities, organizations can gain valuable insights into their network's performance.

Overall, the 3Com VFD-D D combines speed, security, and scalability in a single device, making it a powerful addition to any enterprise network. Its advanced features and technologies are tailored to support the dynamic needs of modern businesses, ensuring reliable performance and robust connectivity in an increasingly interconnected world.