Appendix B How to Select AC Motor Drive DD Series

B-2 General Precautions

Drives Selection

1.When the AC Motor Drive is connected directly to a large-capacity power transformer (600kVA or above) or when a phase lead capacitor is switched, excess peak currents may occur in the power input circuit and the converter section may be damaged. To avoid this, use an AC input reactor (optional) before AC Motor Drive mains input to reduce the current and improve the input power efficiency.

2.When a special motor is used or more than one motor is driven in parallel with a single AC Motor Drive, select the AC Motor Drive current 1.25x(Sum of the motor rated currents).

3.The starting and accel./decel. characteristics of a motor are limited by the rated current and the overload protection of the AC Motor Drive. Compared to running the motor D.O.L. (Direct On-Line), a lower starting torque output with AC Motor Drive can be expected. If higher starting torque is required (such as for elevators, mixers, tooling machines, etc.) use an AC Motor Drive of higher capacity or increase the capacities for both the motor and the AC Motor Drive.

4.When an error occurs on the drive, a protective circuit will be activated and the AC Motor Drive output is turned off. Then the motor will coast to stop. For an emergency stop, an external mechanical brake is needed to quickly stop the motor.

Parameter Settings

1.The AC Motor Drive can be driven at an output frequency up to 400Hz (less for some models) with the digital keypad. Setting errors may create a dangerous situation. For safety, the use of the upper limit frequency function is strongly recommended.

2.High DC brake operating voltages and long operation time (at low frequencies) may cause overheating of the motor. In that case, forced external motor cooling is recommended.

3.Motor accel./decel. time is determined by motor rated torque, load torque, and load inertia.

4.If the stall prevention function is activated, the accel./decel. time is automatically extended to a length that the AC Motor Drive can handle. If the motor needs to decelerate within a certain time with high load inertia that can’t be handled by the AC Motor Drive in the required time, either use an external brake resistor and/or brake unit, depending on the model, (to shorten deceleration time only) or increase the capacity for both the motor and the AC Motor Drive.

B-4

Page 138
Image 138
3Com VFD-D D manual General Precautions, Drives Selection

VFD-D D specifications

The 3Com VFD-D D is an advanced networking solution designed to meet the demands of modern communication and connectivity. As part of 3Com's extensive portfolio of networking products, this device stands out due to its robust features, innovative technologies, and characteristics that cater to various enterprise environments.

One of the main features of the 3Com VFD-D D is its high-speed data processing capability. Operating at speeds that comfortably support high-bandwidth applications, the device is equipped to handle a multitude of simultaneous connections without compromising performance. This makes it an ideal choice for businesses where consistent, fast access to data is critical.

In terms of connectivity options, the VFD-D D supports a variety of protocols, allowing it to seamlessly integrate with existing infrastructure. Whether through Ethernet, Fiber Channel, or wireless technologies, the device offers versatility in connecting diverse network configurations. This adaptability ensures that organizations can optimize their network setups according to their specific requirements.

The 3Com VFD-D D also boasts advanced security features designed to protect sensitive data from potential threats. With built-in encryption protocols and secure access measures, the device safeguards information while offering administrators full control over user permissions. This heightened security is especially important in today's risk-laden digital landscape, providing peace of mind for organizations entrusting their data to the network.

Moreover, the VFD-D D is designed with scalability in mind. Its modular architecture allows businesses to expand their network capabilities as needed, ensuring that the device can grow alongside their evolving requirements. This flexibility helps organizations manage costs effectively while preparing for future technological advancements.

Another characteristic that sets the 3Com VFD-D D apart is its user-friendly management interface. Administration tasks can be performed quickly and intuitively, reducing the burden on IT staff while enabling efficient network monitoring and troubleshooting. With real-time analytics and reporting capabilities, organizations can gain valuable insights into their network's performance.

Overall, the 3Com VFD-D D combines speed, security, and scalability in a single device, making it a powerful addition to any enterprise network. Its advanced features and technologies are tailored to support the dynamic needs of modern businesses, ensuring reliable performance and robust connectivity in an increasingly interconnected world.