Chapter 4 Parameter SettingsDD Series

Open Door (R EV)

04.03Door Open H igh Speed 1

Door Open

04.08

 

 

 

Door Open

 

Door Open

 

 

by Ini tial

 

 

 

04. 09

 

Holding Speed

 

Speed

 

Door Open

 

Door Open

Final Speed

04.07

 

 

04.00

 

Acceleration

 

Deceleration

04.05

 

 

 

 

 

 

Time 1

 

 

Time 1

 

04.06

 

 

 

04.01

 

 

 

 

 

 

 

 

 

 

 

04.04

Door Open

 

 

Door Open D istance

 

 

 

 

 

 

Door Open

by Holding

 

 

by Ini tial Speed

 

 

 

 

 

 

by Final Speed

Speed Begins

 

 

 

 

 

 

05.09

Begi ns

05. 08

05.00

 

 

 

 

05.05

 

 

 

 

05.07

 

 

Door Close

 

D oor Close

Door Close

 

 

Door Close

 

 

Door Close

 

Final Speed

Accel er ation Time 1

Ini tial Speed

 

Holding Speed

Final Speed

 

 

 

 

 

 

 

 

 

 

05.01

 

 

 

 

 

05.04

 

05.03

 

 

 

 

Door Close Limit

05.06

 

 

 

 

Door Close

Door Open Limi t

 

 

Door Close

 

 

 

Door Close

 

 

0.0%

Door Close

High Speed 1

 

 

Distance by

100. 0%

by Final Speed

 

 

 

by Holding

 

 

 

Ini tial Speed

 

 

 

Begi ns

 

 

 

 

 

 

 

 

Speed Begins

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Close Door (FWD)

Door Close Holding Torque

Control mode

VF

VFPG SVC

FOCPG

FOCPM

Factory setting: 20.0

 

 

 

Settings

0.0~100.0% (Drive’s rated current)

 

 

 

 

Response Time of Door Close Holding Torque

 

Control mode

VF

VFPG SVC

FOCPG

FOCPM

Factory setting: 0.20

 

 

 

Settings

0.01~10.00sec

 

 

When the door is in the close complete position, it needs holding torque to keep the door still in complete position. To prevent motor overload, holding torque should be set within a limit.

Door Close High Speed 2

Control mode

VF VFPG SVC FOCPG FOCPM

Factory setting: 30.00

 

 

 

Settings

0.00~120.0Hz

 

 

 

 

Door Close Acceleration Time 2

 

Control mode

VF VFPG SVC FOCPG FOCPM

Factory setting: 1.0

 

 

 

Settings

0.1~3600sec

 

 

 

 

Door Close Deceleration Time 2

 

Control mode

VF VFPG SVC FOCPG FOCPM

Factory setting: 1.0

 

 

 

Settings

0.1~3600sec

 

 

 

 

Door Close Holding Torque Level 2

 

Control mode

VF VFPG SVC FOCPG FOCPM

Factory setting: 0.0

 

 

 

Settings

0.0~150.0% (Ac drive’s rated current)

 

 

 

 

Door Close Time-out Setting

 

Control mode

VF VFPG SVC FOCPG FOCPM

Factory setting: 0.0

 

 

 

Settings

0.0~180.0sec (0.0sec:Disable)

 

 

When the time for door closing is longer than the setting in Pr.05-17, door will re-open.

 

 

 

 

 

 

 

 

Holding Time for CD (Close Door)Terminal

 

Control mode

VF VFPG SVC FOCPG FOCPM

Factory setting: 0.0

 

 

 

Settings

0.0~999.9sec (999.9sec is always holding)

 

This parameter is used to clear the CD terminal signal (door close signal) when door open complete. During the holding period, AC Motor Drive will still be in RUN status. After holding time, AC Motor Drive

4-52

Page 76
Image 76
3Com VFD-D D manual Door Close Holding Torque, Door Close Time-out Setting, Holding Time for CD Close DoorTerminal

VFD-D D specifications

The 3Com VFD-D D is an advanced networking solution designed to meet the demands of modern communication and connectivity. As part of 3Com's extensive portfolio of networking products, this device stands out due to its robust features, innovative technologies, and characteristics that cater to various enterprise environments.

One of the main features of the 3Com VFD-D D is its high-speed data processing capability. Operating at speeds that comfortably support high-bandwidth applications, the device is equipped to handle a multitude of simultaneous connections without compromising performance. This makes it an ideal choice for businesses where consistent, fast access to data is critical.

In terms of connectivity options, the VFD-D D supports a variety of protocols, allowing it to seamlessly integrate with existing infrastructure. Whether through Ethernet, Fiber Channel, or wireless technologies, the device offers versatility in connecting diverse network configurations. This adaptability ensures that organizations can optimize their network setups according to their specific requirements.

The 3Com VFD-D D also boasts advanced security features designed to protect sensitive data from potential threats. With built-in encryption protocols and secure access measures, the device safeguards information while offering administrators full control over user permissions. This heightened security is especially important in today's risk-laden digital landscape, providing peace of mind for organizations entrusting their data to the network.

Moreover, the VFD-D D is designed with scalability in mind. Its modular architecture allows businesses to expand their network capabilities as needed, ensuring that the device can grow alongside their evolving requirements. This flexibility helps organizations manage costs effectively while preparing for future technological advancements.

Another characteristic that sets the 3Com VFD-D D apart is its user-friendly management interface. Administration tasks can be performed quickly and intuitively, reducing the burden on IT staff while enabling efficient network monitoring and troubleshooting. With real-time analytics and reporting capabilities, organizations can gain valuable insights into their network's performance.

Overall, the 3Com VFD-D D combines speed, security, and scalability in a single device, making it a powerful addition to any enterprise network. Its advanced features and technologies are tailored to support the dynamic needs of modern businesses, ensuring reliable performance and robust connectivity in an increasingly interconnected world.