3M 2550 manual Transmitter 2573Keypad and Connector Definitions

Models: 2573 2550

1 70
Download 70 pages 61.42 Kb
Page 10
Image 10

F. Transmitter 2573Keypad and Connector Definitions

Dynatel TM 2573

Trace

 

 

 

 

- + o

on

 

 

 

 

 

off

 

 

Output Level

 

 

T-1

T-2

T-3

T-4

T-5

T-6

T-7

[T-1] off: Turns unit off and performs battery test.

[T-2] on: Ohm-meter/Fault Locate/Tone: Turns the unit on and cycles through the following commands when pressed repeatedly.

Ohm-meter:Measures the continuity of the trace conductor/pipe and its far-end ground. It is also used to measure the fault resistance to earth.

Fault Locate: In this mode, the transmitter sends two alternating locating frequencies (577 Hz and 33 kHz) as well as fault signals 10 and 20 Hz.

Tone: In the tone mode, the transmitter generates 577 Hz and 200 kHz signals. [T-3] on: Trace (frequency): Turns the unit on and places the unit in Trace mode.

Select Frequency: Press Trace [T-3] repeatedly to cycle through the transmitter's active frequencies (577 Hz, 1 kHz, 8 kHz, 33 kHz, 82 kHz and 200 kHz). The selected frequency will be displayed [T-4]. ‘ALL’ indicates that the following active frequencies are transmitting simultaneously: 577 Hz, 8 kHz, 33 kHz and 200 kHz.

[T-4] Digital Display:

Indicator Flags: These flags coincide with the operational mode of the transmitter. (From top left to bottom right) Fault Locate mode [T-2], Tone mode [T-2], Trace mode [T-3], Ohm-meter [T-2], Voltage (at start up the transmitter checks for foreign voltage), and the Output Level [T-5] (no flag = normal output; flag = high output; flashing flag = maximum output).

Digital Display: Indicates frequency, relative current, resistance, battery level and voltage (if present on target).

[T-5] Output Level: Cycles output power level; normal, high and maximum.

Normal=No Flag; High=Flag; Maximum=Flashing Flag (indicated in Digital Display [T-4])

NOTE: An external 12-volt power source is required to obtain Maximum Output level.

NOTE: 12-watt output level varies by frequency. Output is limited to 10 watts at 33 kHz and 1 watt at 82 kHz and 200 kHz using the direct connection method.

[T-6] Output Jack: Port for direct connect cables or Dyna‑coupler cable.

[T-7] External Jack: Port to connect cigarette lighter adapter cable, or rechargeable

battery (2200RB). Input voltage level: 9-18 VDC. (Only on 12-watt transmitters.)

10

78-9000-0192-2 Rev C

Page 10