Special Set-Up Procedure (Continued)

Special Set-Up Procedure (Continued)

Figure 5-2 – Column Re-Positioning

3.Actuate raising switch to release upper assembly latch. (Upper assembly will rest on blocks.) Turn off and disconnect air supply.

4.Remove plastic plugs and M8 x 20 socket head capscrews from (A) and (B) in one side column (4 each). Slide side column up approximately 110 mm [4.25 in] and re-install capscrews in (B) and (C). DO NOT TIGHTEN SCREWS. Repeat procedure for other side column.

5.Using carpenters square, line up column perpendicular to machine bed as shown in Figure 5-2B. Tighten capscrews and install plastic plugs. Repeat this procedure for both columns.

6.Connect and turn on air supply, actuate raising switch and latch upper assembly in full up position.

7.Remove blocking, unlatch and lower upper assembly.