Circuit Breaker

Maintenance (Continued)

WARNING – Turn off electrical and air supplies and disconnect power cord from electrical supply before beginning maintenance. If power cord is not disconnected, severe injury to

personnel could result.

Circuit Breaker

The case sealer is equipped with a circuit breaker which trips if the motors are overloaded. Located inside the electrical enclosure on the side of the machine frame just below the machine bed, the circuit breaker has been pre-set at 1.9 amps and requires no further maintenance.

WARNING – The following procedure must be performed by

trained service personnel because of the high voltage electrical hazard within the control box.

If circuit is overloaded and circuit breaker trips, unplug machine from electrical power:

1.Determine cause of overload and correct.

2.Remove electrical enclosure cover.

3.Press the red "Reset" button and then the green "Start" button.

4.Replace cover.

5.Plug in machine.

6.Press machine "On" button to resume case sealing.