INSTALLATION INSTRUCTIONS
FITTING THE FLUE SPIGOT AND BLANKING PLATE
Note: Blanking plate fitted to top flue outlet for packing
The gas stove is designed so that the flue can be fitted to either the top or the rear of the appliance.
Fit the flue spigot and blanking plate for either top or rear flue outlet in accordance with figure 5a or 5b (below).
Fig. 5a | Fig. 5b |
Lock the blanking hot plate in place by rotating
sealed by the attached gaskets.
Fig 5c
CLOSURE PLATES
If a closure plate is used for sealing off the chimney or fireplace opening it can be made of metal (e.g. aluminium sheet) or fireplace board (see figure 6 a/b/c on page 12) however provision must be made
for checking for debris build up. Closure plates must be sealed to the chimney or fireplace opening with fire cement, fireproof rope or other suitable high temperature mastic.
REAR FLUE OPTIONS
Open Hearth (See Figure 6-a page 12)
Fit and seal a ‘T’ section (with debris /soot collector) directly into the flue spigot. Ensure it passes through the closure plate by at least 102mm (4”).
The maximum horizontal section allowed is 350mm.
Provide a minimum vertical height of 600mm of flue from the height of the rear flue outlet.
Closure Plate (See Figure 6b page 12)
Connect the flue spigot to the rear outlet then connect a flue extension to the spigot up to a maximum length of 350mm.
Fit and seal the closure plate into the fireplace opening.
Position the stove so the flue extension passes through the hole in the closure plate by at least 50mm.
Ensure all joints are sealed with fire cement or a suitable high temperature sealant.
TOP FLUE OPTIONS
Top Flue (See Figure 6c page 12)
Provide a minimum vertical height of 600mm of flue measured from the top of the appliance. Position the stove, with flue spigot in place, into position under the flue and seal the spigot/flue connection with fire cement or a suitable high temperature sealant.
It is recommended that a smoke test is performed inside the stove to ensure that adequate flue draw is evident after making the flue connection
Aarrow Sherborne GSL CF | 11 |