SERVICING
ANNUAL SERVICE
THIS GAS APPLIANCE MUST BE SERVICED EVERY TWELVE MONTHS BY A QUALIFIED GAS ENGINEER.
See "SAFETY NOTICES" ref coal set page 3.
Ensure the appliance is cold.
Step 1 Isolate the gas supply from the stove. Step 2 Remove the outer body of the stove. Step 3 Remove the glass.
Important: If the glass is broken or cracked or the glass gasket is damaged they must be replaced before the stove is used.
Step 4 Carefully remove and clean the loose coal
/logs set of any soot deposits using a soft brush.
Step 5 Clean the firebox of any soot deposits using a soft brush.
Step 6 Carefully lift out and clean the base coal matrix. Important: If any of the ceramic components are damaged they must be replaced with original Aarrow parts.
Step 7 Clean the burner top and surrounding areas with a vacuum cleaner.(See safety notices on page 3).
Step 8 Inspect the pilot assembly to ensure that it is clean, unobstructed and in good work ing order.
Step 9 Looking into the flue from inside the stove check that it is clear of any debris or obstructions.
Step 10 Check the system for gas soundness. Step 11 Check the ignition of the pilot and with
the pilot turned off check that the flame failure system is working.
Step 12 Relocate the base coal matrix (4x piece). Step 13 Relocate and position the loose coals or
Step 14 Light the pilot and check the operation of the stove and the flame picture.
Step 15 Relocate the glass frame assembly, ensuring all the screws are replaced and secure. (Use original screws only.)
Step 16 Refit the dummy fuel retainer.(2x screws) Step 17 Relocate the outer body of the stove. Step 18 If the stove is rear flued proceed to fit the
top flue cover plate into the canopy cutout ensuring the front tab is located under the canopy (see page 25, step 1a). Place the valve cover in front of the control valve.
Step 19 If the stove is top flued, proceed to fit the top flue infill piece (see page 25, step
1b). Place the valve cover in front of the control valve.
CLEANING OUTER SURFACES
It is best cleaned using a soft brush. Do not allow moisture to remain on the top while cold or surface rust may occur.
Aarrow Sherborne GSL CF | 27 |