130 Chapter 3
LCD Module Reassembly Procedure
The Aspire 8940 ships with either a Standard Bezel or Flush Bezel with glass panel LCD Module. The
following sections detail the two distinct procedures, beginning with the Standard Bezel detailed below.

Standard Bezel LCD Module Reassembly—LCD Panel

1. Connect the LCD cable to the panel connector as
shown. 2. Press down the adhesive strip to secure the cable
in place.
3. Run the cable along the back of the panel and press down as indicated to secure the cable in place.
IMPORTANT: Ensure that the LCD cable runs between the green callouts to avoid trapping when the panel is
replaced in the LCD Module.