(2)Overfill Vertical Adjustment Screw

(1) Overfill Horizontal

Adjustment Screw

Fig. 2-1

II. Re-assemble LP module—include LP, LP Baffle, LP clip.

DMD Image Quality

1.Scope

This document specifies the image quality requirements applicable to the DLP®.55XGA Type X, Series 450 Value, and DLPTM .65WXGA-800 Value Component Set. The Component Set provides the DLP®. 55XGA Type X and Series 450 Value Projector with digital imaging functionality based on Digital Micromirror Device (DMD) technology.

2.Definitions: (Defects and Test Screens) Blemish

A blemish is an obstruction, reflection, or refraction of light that is visible, but out of focus in the projected image under specified conditions of inspection (see Table 1). It is caused by a particle, scratch, or other artifact located in the image illumination path.

Dark pixel

A single pixel or mirror that is stuck in the OFF position and visibly darker than the surrounding pixels.

Bright pixel

A single pixel or mirror that is stuck in the ON position and visibly brighter than the surrounding pixels.

Unstable pixel

A single pixel or mirror that does not operate in sequence with parameters loaded into memory. The unstable pixel appears to be flickering asynchronously with the image. Adjacent pixel

Two or more stuck pixels sharing a common border or common point, also referred to as a cluster.

Row or Column Defect

The reset boundary artifact is a single row of pixels on the reset group boundaries that are visibly darker or lighter than the neighboring rows of pixels.

Pond of Mirrors (POM)

POM is a rectangular array of off-state mirrors surrounding the active area. Eyecatcher

Eyecatcher's are blemishes appearing in the area outside of the Active Area. These are due to particles and various DMD window or window aperture “defects”

including: digs, voids, and scratches.