Diagnostics Error M essages

Diagnostic error messages appear at the command line when

running the

aatmdiag.exe

program.

ioctl link failure An error was encountered while doing
I_PLINK or I_PUNLINK between
aarp.sys
,
and
atmo.sys
drivers.
Value <value> out of
bounds The value in the configuration file is out of
bounds.
Diagnostic Error Message Description
Error: Invalid loop
count entered. Must be
positive integer number
A negative or zero loop count is invalid for
the loop command.
Error: Unable to setup
diagnostics. Check if
atmo driver is busy
The driver is busy; several possible causes are
listed below:
Another application is using the
atmo.sys
driver (another
aatmdiag.exe
is currently
active). Terminate the application using the
atmo.sys
driver. For Classical IP, use
acipcnfg.exe
. For an active ARP, use
net stop aarp.
An invalid controller number was specified
while invoking aatmdiag -c #. Valid controller
numbers range from 0 to N, where N is equal
to the total number of physical boards in the
system minus 1. Only one adapter is
supported in a system at this time (enter 0).
The
atmo.sys
driver was not loaded properly.
Reconfigure the driver or reinstall the driver.
SYSTEM Error: No s uch
file or directory File: X The file does not exist when using the aatmdiag
-f X option. Make sure this file exists.