ITEM | SPECIFICATION | COMMENT | |
Power |
|
| |
|
|
| |
AC power ingress | 240 VAC, 20 Amps, single phase |
| |
|
|
| |
Battery backup options |
| ||
extended | 120 minutes | @25 degrees C (degrees F) | |
glitch | 5 minutes | for four bands | |
|
|
| |
RAN box power use | 2700 Watts Max. |
| |
| 16 Amps Max. |
| |
|
|
| |
cPCI rack power |
| ||
|
|
| |
Optical |
|
| |
|
|
| |
Fiber cable ingress | Nylon connector accommodates | For larger cable sizes, refer to the | |
| cable diameters in range 0.38- | note in Section 1.6.2 on Page 9. | |
| 0.50 inches |
| |
|
|
| |
Fiber type | Corning |
| |
|
|
| |
Optical connectors | LC | Standard on SFP transceivers | |
|
|
| |
Insertion loss | 0.2 dB Typical, 0.4 dB Max. |
| |
|
|
| |
Number of fibers required |
| ||
|
|
| |
Fiber configuration | Star (point to point) or ring | Ran ring limited to 3 SIFs | |
|
|
| |
Fiber data link protocol |
| ||
|
|
| |
Wavelengths per fiber | 1 (1310 nm) | Without WDM/CWDM option | |
with WDM option | 2 (1310/1550) |
| |
with CWDM option | 8 | 20 nm increments | |
|
|
| |
Optical transceiver type | SFP | Dual LC connector | |
|
|
| |
Optical Tx power | Finistar | ||
|
| (or equivalent) | |
Optical Rx sensitivity | |||
| |||
|
|
| |
Optical link margin | 2 dB | Estimated | |
|
|
| |
Optical link loss | 6 dB | Estimated | |
|
|
| |
Optical Rx saturation level | Min. Max. operational power | ||
|
|
| |
Optical Rx damage level | Min. Max survivable power | ||
|
|
| |
Optical safety class | 1 | ANSI Z 136.2 | |
|
|
| |
RF |
|
| |
|
|
| |
Tuning frequency | Receive Path | Transmit Path | |
PCS band | |||
Cellular band | |||
SMR 800 band | |||
SMR 900 band | |||
|
|
| |
Instantaneous bandwidth | 15 MHz |
| |
|
|
| |
Receiver noise figure |
| Measured at Hub output connec- | |
PCS band | 6 dB | tor (BIM, RxP) without BTS at 10 | |
Cellular band | 5 dB | dB gain and a single RAN | |
|
|
|
Page 7