This module also provides a CW test tone for use in reverse continuity testing. The RF signals are input into the module by way of coax cables terminated with SMA connectors on the faceplate (at the ports labeled PRI IN and DIV IN). Figure 13 shows the module faceplate. Table 8 describes the module faceplate components called out in the figure.
PRIMARY
IN 1
DIVERSITY
IN
2
FAULT
LED
3
POWER
LED 4
REF # | DESIGNATION | DEVICE | FUNCTIONAL DESCRIPTION |
1 | PRI IN | SMA connector | Primary In. Receives RF primary output from either C/PMC- |
|
|
| PLR or P/MCPLR module. Connection is made using cable |
|
|
| 1955000P081 |
|
|
|
|
2 | DIV IN | SMA connector | Diversity In. Receives RF diversity output from either C/ |
|
|
| PMCPLR or P/MCPLR module. Connection is made using |
|
|
| cable 1955000P081 |
|
|
|
|
3 | FLT | Red LED | Fault. Lights when module has failed and during |
|
|
| module has initialized; blinks after module receives a system |
|
|
| clock and is awaiting initialization |
|
|
|
|
4 | PWR | Green LED | Power. Lights when module has power |
|
|
|
|
Page 18
© 2007, ADC Telecommunications, Inc.