UTILITY POLE
MOUNTING BRACKET
2.63IN. (6.7 CM)
|
| RAN | |
|
| ||
13.5 IN. | ATTACHMENT | ||
POINTS | |||
(34.3 CM) | |||
|
34.5 IN.
(87.6 CM)
29.25IN. (74.3 CM)
HOT DIPPED GALVANIZED MACHINE
BOLT SQUARE HEAD 3/4 x 16.00 LG
W/NUT (J9816) 3 REQUIRED
10 FT.
ROUND FLAT WASHER 2.00 O.D.
(3 M)
(J1089) 3 REQUIRED
TYPICALSQUARE CURVED WASHER 3 x 3 x 1/4 (J6823) 3 REQUIRED
SPRING LOCK WASHER
.234 x.188 (J140) 3 REQUIRED
OR EQUIVALENT
Figure 26. Cabinet Mounting Bracket
2.Place the pole mount bracket against the pole.
3.Strap or otherwise hold the bracket in place.
4.Using a level, adjust the bracket to make it vertically level.
5.Mark the three holes to be drilled through the wood pole.
6.Remove the pole mount bracket.
7.Drill three holes through the pole using a 7/8 in. wood bit.
8.Using a 3/4 in. machine bolt, put a 2 in. flat washer on the bolt.
9.Place the pole mounting bracket against the pole.
10.Align the holes in the bracket with the holes drilled in the pole.
11.Install one bolt through the bracket and pole (using any of the three holes).
12.Place a 3 in. square curved washer, lock washer, and 3/4 in. nut on the other end of the machine bolt; do not tighten.
13.Repeat steps
14.Using a
Page 37
© 2007, ADC Telecommunications, Inc.