ADCP-75-210 • Issue 1 • March 2007

3.Slide the RDC module into the designated slot within the RAN chassis.

4.Lock the IEL handles on the top and bottom of the RDC module into the chassis and tighten the handle screws.

5.Using an SMA coaxial cable (1955000P081), connect one end to the PRI IN port on the RDC module and the other end to the appropriate P OUT port on the C/MCPLR or P/ MCPLR module. Each P OUT port is associated with a different band.

Note: For more information on the C/MCPLR module ports, see Section 1.7.9, 800 MHz Multicoupler (C/MCPLR), on page 20. For more information on the P/MCPLR module ports, see Section 1.7.10, 1900 MHz Multicoupler (P/MCPLR), on page 22.

6.Using an SMA coaxial cable (1955000P081), connect one end to the DIV IN port on the RDC module and the other end to the appropriate D OUT port on the C/MCPLR or P/ MCPLR module. Each D OUT port is associated with a different band. For more information on these ports, refer to the sections identified in the note above.

21235-AX

Figure 45. Installing an RDC Module

4.1.6Installing a RAN Up Converter (RUC2.X or RUC3) Module

The RAN Up Converter (RUC2.X or RUC3) module may be installed into either of two slots in the RAN chassis, depending on the band for which the module will be used. One module is required for each two bands. The two slots are:

Slot 11 (labeled RUC A2): used for first and second bands

Slot 14 (labeled RUC A5): used for third and fourth bands

Page 64

© 2007, ADC Telecommunications, Inc.