ADCP-75-210 • Issue 1 • March 2007

(Pad mount only) Four 1/2 in. diameter galvanized steel bolts with four lock washers, four flat washers, and four concrete anchors (see Figure 29 on Page 41)

3M 8426-9M cold shrink

3M Skothkote Electrical Coating 14853

Ten Type N plugs (CommScope PN: 540ANM or equivalent)

Coaxial cable (CommScope PN: FXL540OPE or equivalent)

Electrician’s tape

Water seal

Electrical conduit

Conduit fittings

Connector sealant material

Panduit LLCF6-14B-L or equivalent (X2)

Two-hole compression lug terminal for #6 AWG wire

Ground rod

Connector for attaching #6 AWG grounding wire to approved ground source

The following tools are required to perform this procedure:

Torque wrench

Drill

Drill bit (appropriate for pole width and 3/4 in. bolts)

7/16 in. open-end wrench

Compression pliers for #6 AWG grounding lug

Wire cutters

Wire strippers

Conduit cutter

Conduit bender

2.4Site Preparation

This section describes site preparation for installation and is presented only as a guideline for a typical RAN installation.

2.4.1Space Requirements

When an installation site for the RAN is selected, either on a utility pole or concrete pad, care must be exercised to ensure that the site provides adequate space and clearance to accommodate the current installation and any future upgrades. Table 17 gives RAN dimensions.

Page 32

© 2007, ADC Telecommunications, Inc.