Port event selection: Also, before the drop-down menu items are available, the Syslog Client Mode column on the Syslog Configuration tab/E-mail Alert column on the SMTP Configuration tab must be enabled first. Those drop-down menu items have 3 selections—Link UP, Link Down, and Link UP & Link Down. Disable means no event will be sent to the system log server/SMTP server.

¾Link UP: The system will issue a log message when port connection links up only.

¾Link Down: The system will issue a log message when port connection links down only.

¾Link UP & Link Down: The system will issue a log message when port connection is up and down.

Figure 3.18: Event Configuration

Fault Relay Alarm

Power Failure: Tick the checkbox to enable the function of lighting up the FAULT LED on the panel when power fails.

Port Link Down/Broken: Tick the checkbox to enable the function of lighting up FAULT LED on the panel when ports’ states are link-down or broken.

49

Chapter3

Page 59
Image 59
Advantech EKI-7657C user manual Event Configuration, Fault Relay Alarm