COM1 and COM2 are one set. You can exchange the address range and interrupt IRQ of COM1 for the address range and interrupt IRQ of COM2. After exchanging, COM1's address range is 2F8 ~ 2FF and its request IRQ is IRQ3: and COM2's address range is 3F8 ~ 3FF and its interrupt IRQ is IRQ4.

COM3 and COM4 are another set. Their selectable function is the same as the COM1/COM2 set.

Table 5-13: PPC-120/140 serial port default settings

Port

Address Range

Interrupt

COM1

3F8 ~ 3FF

IRQ4

 

 

 

COM2

2F8 ~ 2FF

IRQ3

 

 

 

COM3

3E8 ~ 3EF

IRQ10

 

 

 

COM4

2E8 ~ 2EF

IRQ5

 

 

 

5.3.2 COM3/COM4/RI pin setting (JP2, JP1) (Reserved)

Table 5-14: COM4/RI pin setting (JP2)

+5 V output

+12 V output

* RI output

6

4

2

5

6

3

4

1

2

5

6

5

3

4

3

1

2

1

* default setting

Table 5-15: COM3/RI pin setting (JP1)

+5 V output

+12 V output

* RI output

6

4

2

5

6

3

4

1

2

5

6

5

3

4

3

1

2

1

* default setting