Open Problem Reports and Feature Exceptions

PR 106213

When using "configuration apply" to apply routing configuration to an OS6850 system that has completed its boot up, parts of the configuration may fail with a "system busy" error.

Workaround: 1) Ensure that the protocol is manually loaded prior to applying the configuration file. For example,

>ipv6 load ospf

>configuration apply ospf3.asc.1

2)(Optional) After configuring the protocol, use a "write memory" to commit the changes to the boot up configuration file.

Server Load Balancing (SLB)

Problem Reports

PR 105700

For SLB clusters on OS9000, there are no statistics or flow distribution metrics on a server basis. The only server statistic is the number of packets passed to a cluster.

Workaround: There is no known workaround at this time.

PR 107490

When executing a “show ip slb cluster <clustername>” CLI command on a non-existing SLB cluster name more than 23 characters long, an “slbCtrl” STR is generated. However, no adverse conditions are seen with the switch.

Workaround: There is no known workaround at this time.

UDP Relay

Problem Reports

PR 97666

TCP does not send an RST after receiving an unacceptable ACK in SYN-RCVD state on OS6800 and OS6850.

Workaround: There is no known workaround at this time.

page 68

OmniSwitch 6800/6850/9000—Release 6.1.3.R01

Page 68
Image 68
Alcatel-Lucent 6850, 9000, 6800 user manual Server Load Balancing SLB, UDP Relay