Open Problem Reports and Feature Exceptions

PR 99862

When an over stressed test caused 100% CPU usage on an OS6850, the "Unable to send running check- sum" message was displayed, and the switch was rebooted.

Workaround: Avoid 100% CPU usage.

PR 100127

By default, an OS6850 switch is configured to run in strict-priority. If over-subscription is done on priori- ties 6 & 7, it will bring down the switch.

Workaround: Over-subscription on priorities 6 & 7 is not yet supported on the switch. Do not configure the over subscription with priority 6 or 7.

PR 105381

The flash file system on an OS6850 shows no space but allows copy anyway.

Workaround: Remove any unneeded files before performing copy.

PR 105646

The entPhysicalModelName MIB variable returns vendor name of SFP instead of model name for an SNMP get/getNext call to this object on an OS6850.

Workaround: There is no known workaround at this time.

PR 106559

Output to STDOUT is re-directed to the PMD file on an OS9000. A printf is occurring that causes the “show log” command to fail.

Workaround: The contents of the pmd file can still be viewed with vim, gvim, etc. as most of the contents are ascii strings.

PR 106812

The "update default miniboot" is still supported on OS6850 even though there is no default or backup miniboot.

Workaround: This command will still cause the miniboot to be updated properly.

PR 106649

The “update miniboot” command is not working on OS-9000.

Workaround: Use the “update uboot-miniboot” command to update the miniboot.