Open Problem Reports and Feature Exceptions
PR 107284
Supplicant and
Workaround: View the
PR 107315
A duplicate slot in a stack of switches will not display the switch picture in the WebView > Chassis Mgmt > Chassis homepage.
Workaround: Remove the duplicate slot.
PR 107529
WebView Networking > IP > BGP > Policy Route Maps Modify help "local Preference Value" hyperlink is broken.
Workaround: There is no known workaround at this time.
PR 107530
When using the Netscape browser to access the WebView > Policy > Policy > Ports page after clicking on either "Previous" or "Next" buttons and then clicking on the "Refresh" button, a "method not allowed" error is displayed.
Workaround: Click on the "Ports" menu to refresh.
Layer 2
Autonegotiation
Problem Reports
PR 86826
On an OS6800/OS9000, when autonegotiation is disabled and speed is forced to 10 Mbps, copper ports may confuse with a forced 100Mbps link partner and can detect a false link UP. Traffic may not pass in this condition.
Workaround: Enable autonegotiation for this copper port and configure desired speed and duplex settings.
OmniSwitch | page 53 |