Open Problem Reports and Feature Exceptions

PR 107287

During "update lanpower all" on a stack of 8 OS6850-P24/48, you might see the following error message:

THU OCT 12 14:06:27 : LANPOWER (108) error message:

+++Unable to Read S19 Response! Reset Daughter Module!

Done

THU OCT 12 14:48:59 : LANPOWER (108) error message:

+++Unable to Read BOOT_SECTION_RESPONSE Response!

+++General Programming Error!

Workaround: Do a "lanpower start" on the NI which failed the firmware update. Once lanpower failed to start which is expected, you then try to "update lanpower <slot>" again on that specific NI.

Redundancy / Hot Swap

Hot Swap Time Limitations for OmniSwitch 9000

All removals of NI modules must have a 30 second interval before initiating another hot swap activity.

All insertions of NI modules must have a 3 minute interval before initiating another hot swap activity.

All hot swaps of CMM modules must have a 10 minute interval before initiating another hot swap, reload or takeover activity.

All takeovers must have a 10 minute interval before following with another hot swap, reload or take- over activity.Problem Reports

Problem Reports

PR 91287

After takeover, the new primary CMM does not keep the DOS statistics held by the previous primary CMM.

Workaround: There is no known workaround at this time.

PR 95840

The whole chassis will reload if more than half of NIs are hot swapped in and out of the chassis at roughly the same time.

Workaround: If hot swap of NIs is required, a user may have to wait until a previous NI has been booted first, and then hot swap the next NI.

page 84

OmniSwitch 6800/6850/9000—Release 6.1.3.R01

Page 84