Installation

Pre-Installation Inspection

Upon delivery, visually inspect the crate, carton and
parts for any visible shipping damage. If the crate,
carton or cover is damaged or signs of possible
damage are evident, have the carrier note the condition
on the shipping papers before the shipping receipt is
signed, or advise the carrier of the condition as soon as
it is discovered.
Remove the crate and protective cover as soon as
possible and check the items listed on the packing list.
Advise the carrier of any damaged or mi ssing articles
as soon as possible. A written claim should be filed
with the carrier immediately if articles ar e damaged
or missing.
IMPORTANT: Warranty is void unless tumble
dryer is installed according to instructions in this
manual. Installation should comply with minimum
specifications and requirements detailed in this
manual and applicable local gas fitting regulations,
municipal building codes, water supply regulations,
electrical wiring regulations, and any other
relevant statutory regulations. Due to varied
requirements, applicable local codes should be
thoroughly understood and all pre-installation
work arranged for accordingly.
IMPORTANT: Keep tumble dryer area clear and
free from combustible materials, gasoline and other
flammable vapors and liquids.

Location Requirements

The tumble dryer must be installed on a level floor.
Floor covering materials such as carpeting or tile must
be removed.
To assure compliance, consult local building code
requirements. The tumble dryer must not be installed
or stored in area where it will be exposed to water and/
or weather.
IMPORTANT: DO NOT block the airflow at the
rear of the tumble dryer with laundry or other
articles. Doing so would prevent adequate air
supply to the combustion chamber of the tumble
dryer.
A typical tumble dryer enclosure is shown in Figure 1.
Note the minimum and maximum dimensions. Local
codes and ordinances must be complied with.
Materials Required (Obtain locally)
All Models One Single Pole fused disconnect
switch or circuit breaker on 1 Phase
models.
Circuit breaker on 3 Phase models.
Gas Models One gas shut-off valve for gas
service line to each tumble dryer.
Steam Models One steam shut-off valve for steam
service line to be connected upstream
of solenoid steam valve.
Two steam shut-off valves for each
condensate return line.
Flexible steam hoses with a 125 psig
(pounds per square inch gauge)
(8.79 kg/sq. cm) working pressure
for connecting steam coils. Refer to
Figure 14 and Figure 15 or sizing
and connection configurations.
Three steam traps for steam coil
outlet to condensate return line.
Optional – Three vacuum breakers
for condensate return lines.