© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
17
70420801 (EN)
IMPORTANT: Install tumble dryers with sufficient
clearance for servicing and operation. Refer to
Figure 1.
Figure 1
To reduce the risk of serious injury, install
lockable door(s) to prevent public access
to rear of tumble dryers.
W055R1
WARN ING
TMB2020N
NOTE: Shaded areas indicate adjacent structure.
10.5 in. (13 mm) recommended between machines for removal or installation.
2Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.
34 in. (102 mm) maximum header thickness
4Minimum clearance permitted for remainder: Gas 4 in. (102 mm), Steam 12 in. (305 mm)
5Guard
6Provision for Make-Up Air
724 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes
80.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed
TMB2020N
4
1
5
6
7
3
WARN ING
To reduce the risk of severe injury, clearance of tumble dryer cabinet from combustible
construction must conform to the minimum clearances.
W056R1
8
2