© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Gas Requirements
70420801 (EN)
32
Figure 10
Turn on gas and check all pipe connections (internal
and external) for gas leaks with a non-corrosive leak
detection fluid. Purge air in gas service line by
operating the tumble dryer in the drying mode. If
burner does not light and unit goes into lockout, open
and close the door and restart. Repeat these steps until
burner ignites. Use pipe compound, resistant to
actions of L.P. Gas, on all pipe threads.
TMB2317N
1Gas Line to tumble dryer Controls
2Gas Supply Piping System
3Gas “T” Fitting
46 in. (152 mm) Minimum Gas Pipe
5Gas Pipe Cap
6Sediment Trap
12
3
4
5
6
WARN ING
Check all pipe connections, internal and
external, for gas leaks using a non-
corrosive leak detection fluid. To reduce
the risk of explosion or fire, DO NOT USE
AN OPEN FLAME TO CHECK FOR GAS
LEAKS! Gas connections should be
checked twice a year for leakage.
W635