© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
21
70420801 (EN)
Gases and Configurations
Burner orifice information at 0-2000 feet (0-600 meters) altitude.
* For Natural Gas, Group E+ applications, convert using L.P.
Gas model and replace burner orifices.
** For L.P. Gas, Group B/P with 50mbar supply pressure,
convert using Natural Gas model and appropriate burner
orifices.
Country
Code Gas Type Group
Supply
Pressure,
mbar
Burner
Orifice
Pressure,
mbar
Capacity/
Model
Diameter,
mm Quantity
Burner
Orifice
Part No.
DK/NO/
SE/FI/CZ/
EE/LV/LT/
SI/SK
Natural Gas E 20 8.9
8.0
120
170
4.8
4.8
3
4
M411372
M411372
L.P. Gas B/P 30 No Governor 120
170
2.6
3.4
3
3
M411376
M400997
DE**
Natural Gas E 20 8.9
8.0
120
170
4.8
4.8
3
4
M411372
M411372
L.P. Gas B/P 30 and No Governor or 26.4
or
50** and No Governor or
28.7
120
170
2.6
3.4
3
3
M411376
M400997
NL
Natural Gas LL 25 12.0 120
170
4.8
4.8
3
4
M411372
M411372
L.P. Gas B/P 30 No Governor 120
170
2.6
3.4
3
3
M411376
M400997
BE/FR*
Natural Gas E+ 20 No Governor 120
170
3.7
3.7
3
4
M400998
M400998
25 No Governor 120
170
3.9
3.9
3
4
M402997
M402997
L.P. Gas 3+ 30 No Governor 120
170
3.0
3.5
3
3
M401017
M400997
37 No Governor 120
170
3.1
3.5
3
3
70070903
M400997
GB/IE/PT/
ES/IT/GR/
LU/CH
Natural Gas E 20 8.9
8.0
120
170
4.8
4.8
3
4
M411372
M411372
L.P. Gas 3+ 28 or 37 No Governor 120
170
2.6
3.4
3
3
M411376
M400997
AT**
Natural Gas E 20 8.9
8.0
120
170
4.8
4.8
3
4
M411372
M411372
L.P. Gas B/P 50** 26.4
28.7
120
170
2.6
3.4
3
3
M411376
M400997
CY/IS/MT
L.P. Gas B/P 30 No Governor 120
170
2.6
3.4
3
3
M411376
M400997
HU
Natural Gas H 25 8.9
8.0
120
170
4.8
4.8
3
4
M411372
M411372
L.P. Gas B/P 30 No Governor 120
170
2.6
3.4
3
3
M411376
M400997
PL
Natural Gas H 20 8.9
8.0
120
170
4.8
4.8
3
4
M411372
M411372
L.P. Gas 3P 37 No Governor 120
170
2.6
3.4
3
3
M411376
M400997
Table 2