© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Adjustments
70420801 (EN)
48
Airflow Switch
The airflow switch is set at the factory for proper
operation. No adjustment necessary.
The airflow switch operation may be affected by
shipping tape still in place, lack of make-up air, or an
obstruction in the exhaust duct. These should be
checked and the required corrective action taken.
IMPORTANT: Airflow switch vane must remain
closed during operation. If it opens and closes
during the drying cycle, this indicates insufficient
airflow through the tumble dryer. If switch remains
open, or pops open and closed during the cycle, the
heating system will shut off. The cylinder and fan
will continue to operate even though the airflow
switch is indicating insufficient airflow.
NOTE: To properly mount the airflow switch
bracket, or in case of a load not drying, the airflow
switch bracket may need to be checked for proper
alignment. Be sure the locator pins are securely in
their respective holes before tightening the bracket
mounting screws. This will assure proper
alignment of the airflow switch arm in the chan nel
of the airflow switch bracket and prevent binding
of the arm.
Loading Door Strike
The loading door strike must be adjusted to have
sufficient tension to hold loading door clos ed against
force of load tumbling against it. Proper adjustment is
when 8-15 pounds (35.6-66.7 N) pull is required to
open door.
If adjustment is required, refer to Figure17 and
proceed as follows:
To adjust, open door, loosen jam nut and turn door
strike screw in or out as required. Retighten jam nut.
Figure 17
Loading Door Switch
Loading door switch is factory set; no field adjustment
necessary.
WARN ING
The tumble dryer must not be operated if
the airflow switch does not operate
properly. Faulty airflow switch operation
may cause an explosive gas mixture to
collect in the tumble dryer.
W072R1
T048I
1Door Strike
2Door Latch
3Jam Nut
2
3
1