© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Requirements
70420801 (EN)
40
To Connect Electrical Service to the Tumble Dryer
NOTE: The wiring diagram is located in the
junction or contactor box.
1. Install a circuit breaker as close to the tumble
dryer as possible. If more than one tumble dryer
is being installed, a circuit breaker should be
provided for each. This will make it possible to
disconnect each tumble dryer for maintenance
purposes.
2. Connect conduit-encased leads to the circuit
breaker. Connect wire leads to the appropriate
labeled terminal on the terminal block. The
ground wire must be connected to the ground
connection as shown in Figure 12.
3. Check the electrical service phase sequence
(three phase only). If one of the power leads is a
“high leg,” connect it to lead L3 in the tumble
dryer. The cylinder must rotate clockwise and the
fan must rotate counterclockwise (as viewed
from the front of the tumble dryer – with selector
switch in non-reverse position). If not,
interchange leads L1 and L2 in the tumble dryer
connection box.