Steam Requirements
70420801 (EN)
46
170 Pound Tumble Dryers
Figure 15
TMB2024N
NOTE: Refer to Table 11 for sizing of steam lines. Piping must also be sized accordingly for length of runs and
number of elbows.
1Risers 12 in.
(305 mm) 618 in. Drop (457 mm)
2Shut-Off Valve 7Steam Bonnet
3Check Valve 8Solenoid Valve (Supplied with machine)
4Vacuum Breaker (optional) 9Union
5Condensate Return Line from Supply Line 10 Trap with Built-In Strainer
TMB2024N
SUPPLY
2
1
9
3
RETURN
2
3
710
4
5
8
6
Model Steam Pressure
PSI (bar)
Minimum
Supply Pipe Diameter
Steam Trap Size *
(Pounds Condensate/Hour)
170S 80-100 (5.3-6.9) 1-1/4 in. NPT 517
* Based on maximum psi.