Electrical Requirements
NOTE: To ensure protection against shock, this
tumble dryer MUST be electrically grounded in
accordance with the local codes or, in the absence of
local codes, with the latest edition of the Nati onal
Electrical Code ANSI/NFPA No. 70. In Canada the
electrical connections are to be made in accordance
with CSA C22.1 latest edition Canadian Electrical
Code, Part I and/or local codes. Electrical work
should be done by a qualified electrician.
IMPORTANT: Electrical connections must be
made by a qualified electrician using data on serial
plate, installation manuals and wiring diagram
provided with machine and according to local
codes. Install a circuit breaker as close to the
tumble dryer as possible. If more than one tumble
dryer is being installed, a circuit breaker must be
provided for each.
NOTE: Connect machine to an individual branch
circuit not shared with lighting or other equipment.
NOTE: 3 Phase Machines Only - Do not use fuses
to avoid the possibility of “single phasing” and
causing premature failure of the motors.

Grounding Instructions

This tumble dryer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. This tumble dryer must
be connected to a grounded metal, permanent wiring
system; or an equipment grounding conductor must be
run with the circuit conductors and connected to the
appropriate ground location.
Metal conduit and/or BX cable is not considered
ground. Connecting the Neutral from the electrical
service box to the tumble dryer ground screw does not
constitute a ground. A dedicated ground conduit (wire)
must be connected between the electrical service box
ground bar and the tumble dryer ground screw.
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the tumble
dryer before servicing.
• Close gas shut-off valve to gas tumble
dryer before servicing.
• Close steam valve to steam tumble dryer
before servicing.
• Never start the tumble dryer with any
guards/panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumble dryer is properly grounded.
W002R1
To reduce the risk of fire and electric
shock, check with a qualified serviceman
for proper grounding procedures.
Improper connection of the equipment
grounding conductor may result in a risk
of electric shock.
W068
To reduce the risk of fire and electric
shock, if electrical supply is coming from a
three phase service, DO NOT connect a
“High Leg” or “Stinger Leg” to a single
phase machine. On a three phase machine,
if there is a “High Leg” or “Stinger Leg” it
should be connected to L3.
W069
WARN ING
WARN ING
In case of servicing (or putting the tumble
dryer out of order), disconnect the tumble
dryer from the main supply by switching
off the circuit breaker.
W796