Position and Level the Tumble Dryer
The tumble dryer may be moved with or without the
skid. To remove the skid, unscrew the four shipping
bolts, and discard them.
To fit a 170 pound tumble dryer (with shipping skid)
through an 8 foot (2.43 meters) high door, you must
remove the front access panel. The upper 3 inches
(76 mm) of the stove must also be removed on
170 pound gas tumble dryers. Removing the entire gas
or steam heater assembly and the shipping skid, will
reduce the height of the 120 pound tumble dryer to 70
inches (1778 mm), and the 170 pound tumble dryer to
75 inches (1905 mm).
Level the tumble dryer to within 0.125 inch (3 mm)
from front-to-rear (level on cylinder rib) , and side-to-
side (level on top panel). Shim under corners to level
and stabilize unit. Tumble dryer must not rock.
Before Placing Tumble Dryer into Service
1. Remove or open all panels and check accessible
bolts, nuts, screws, terminals and fittings f or
tightness.
2. Check V-belt tension and adjust if necessary.
Refer to appropriate paragraphs in Adjustments
Section.
3. Replace all panels and guards.
4. Turn on electrical supply to tumble dryer.
5. Open supply valve for gas or steam heated
tumble dryers.
6. After performing the previous checks, start
the tumble dryer by pressing START (hold for
approximately 3 seconds). Release the start
button and open the loading door. The cylinder
should stop rotating within 7 seconds after th e
door is opened.
7. Gas tumble dryers: Start the tumble dryer and
check the burner flame. Adjust the gas inlet
shutter as required. Refer to Adjustments section.
IMPORTANT: The Electronic Ignition system will
attempt to light the gas by sparking for the “trial
for ignition” period. If gas does not ignite within
this period, the ignition control will go into a safety
lockout and the valve will no longer open until the
control is reset. R efer to Tab le 1. It may be
necessary to restart several times to bleed air out of
gas lines. To reset, open and close loading door,
then start.
If lockout condition persists, check that the manual
gas shut-off valve is in the open position and that
the gas service is properly connected. If condition
still persists, remove tumble dryer from servi ce.
8. Load the cylinder with a full load of clean rags
and run to remove oil or dirt from cylinder.
Location
Prepurge
Time
(seconds)
Trial f or
Ignition
(seconds)
Reset
Lockout
Condition
By:
CE and
Australia 18 10
Press and
hold reset
button on
junction box
until light
goes out.
All others 1-3 10 Open loading
door.
Table 1