Alliance Laundry Systems CI 1650/325, CI 2050/325 instruction manual Diameter

Models: CI 1650/325

1 65
Download 65 pages 49.37 Kb
Page 18
Image 18
Diameter

3

In order to ensure a satisfactory function of the machine exhaust system, the subsequent pipe system that is installed in the laundry, should as minimum be dimensioned according to the following guidelines. If the pressure loss in the piping system is increased as a result of dimensioning faults, this will cause a reduction of the exhaust and thus the machine capacity.

In case of short distances between the ironer and the outlet to the outside, i.e. less than 15m including allowance for bends, the exhaust pipe can be made as a channel with diameter 125mm for all machine types.

In case of longer distances, we recommend to use a larger pipe diameter. When judging the exhaust channel, see the following tables that deal with pressure loss and the dynamic pressure by different pipe dimensions and also deal with the equivalent pipe lengths for different part elements in an exhaust channel.

Dynamic pressure (Pd) in [Pa] and specific pressure loss (∆p) in [Pa/m] dependent on volume flow in m³/h and pipe diameter (dia) in mm. S is the speed in m/s.

Diameter

 

100

 

 

125

 

 

150

 

Volume

Pd

∆p

S

Pd

∆p

S

Pd

∆p

S

m³/hour

Pa

Pa

m/s

Pa

Pa

m/s

Pa

Pa

m/s

250

47

14

8,8

19

4

5,7

9

2

3,9

350

93

26

12,4

38

8

7,9

18

3

5,5

450

153

42

15,9

63

13

10,2

30

5

7,1

550

229

62

19,5

94

19

12,4

45

7

8,6

650

320

85

23,0

131

26

14,7

63

10

10,2

750

426

112

26,5

174

34

17,0

84

13

11,8

850

547

143

30,1

224

44

19,2

108

17

13,4

950

683

178

33,6

280

54

21,5

135

21

14,9

1050

834

217

37,1

342

66

23,8

165

25

16,5

1150

1001

259

40,7

410

79

26,0

198

30

18,1

1250

1182

305

44,2

484

92

28,3

234

35

19,6

1350

1379

355

47,7

565

107

30,6

272

41

21,2

 

 

 

 

 

 

 

 

 

 

Diameter

 

160

 

 

180

 

 

200

 

Volume

Pd

∆p

S

Pd

∆p

S

Pd

∆p

S

m³/hour

Pa

Pa

m/s

Pa

Pa

m/s

Pa

Pa

m/s

250

7

1

3,5

5

1

2,7

3

0

2,2

350

14

2

4,8

9

1

3,8

6

1

3,1

450

23

4

6,2

15

2

4,9

10

1

4,0

550

35

5

7,6

22

3

6,0

14

2

4,9

650

49

7

9,0

30

4

7,1

20

2

5,7

750

65

10

10,4

41

5

8,2

27

3

6,6

850

83

12

11,7

52

7

9,3

34

4

7,5

950

104

15

13,1

65

8

10,4

43

5

8,4

1050

127

18

14,5

79

10

11,5

52

6

9,3

1150

153

22

15,9

95

12

12,6

63

7

10,2

1250

180

25

17,3

113

14

13,6

74

8

11,1

1350

210

29

18,7

131

16

14,7

86

9

11,9