Page 22
Image 22
Basic checks

3

Basic checks

Important

The first start-up of the machine should only be performed by an authorized service engineer or a distributor.

In special cases, it may be allowed that the first start-up is performed by the customer, but only after thorough instruction.

WARNING

If the first start-up is performed on one's own initiative, this may cause damage to persons, things, or environment.

-Check if all safety guards with interlocking device are closed, and that all emergency stop devices have been deactivated.

-Start the machine.

All machines have been tested and adjusted from the factory. However, factors such as temperatures, moisture of the atmosphere etc. may imply that an adjustment is necessary at the set-up place.

Ventilation of the room

The machine is fitted with a ventilator. This ventilator ensures vaporized moisture, and with a gas- heated ironer the flue gases, being exhausted.

It is important that the room, in which the ironer has been installed, is sufficiently ventilated. You have to take the universal rules for laundry environments into account together with the fact that the ironer exhausts 350 m³/h. It is also important that sufficient fresh air can enter the room.

Check this before you start the machine!

22