Exhaust system

3

Exhaust system

Whenever possible, install the ironer along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed. The construction must not block the airflow at the rear of the ironer.

Doing so would prevent adequate air supply to the ironer combustion.

For maximum efficiency, ironer air must be exhausted to the outdoors by the shortest possible route.

Note

Never connect an ironer duct at a 90° angle to the collector dust (see picture below). Doing so will cause excessive back pressure, resulting in poor performance.

Never connect two ironer exhaust ducts directly across from each other at the point of entry to the collector dust.

Number of ironers

D1

D2

D3

Diameter of the exhaust pipe (in mm)

100

150

225

Ventilation aperture required section (in dm²)

0,8

1,8

4

D1

D2

D2

1

2

17