Alliance Laundry Systems CI 1650/325, CI 2050/325 Description of the control system

Models: CI 1650/325

1 65
Download 65 pages 49.37 Kb
Page 44
Image 44
Description of the control system

6

Description of the control system

General description of the control system

The control system consists of a microprocessor board with built-on display and push-buttons.

Electric heating control

For the electric heated version, the relays for the heating elements are controlled by a time related P.I.D. controlled function built in the program of the processor, which has the opportunity of a quick reaction with limited overshoot. The elements are activated by relays.

Gas heating

With the gas version, a PWM controlled ventilator is used, which is controlled by the microprocessor.

This ventilator blows the mix of gas and air into the burner, which means that the power of the burner is controlled by the microprocessor. The advantage is that also here the burner is controlled with a P.I.D. controlled function from 20-40 to 100% so that there is a quick reacting system with a low overshoot.

When the need of power is lower than 15%, the burner will be temporarily switched off.

Temperature control

The temperature of the roll is measured by Pt1000 elements that are mounted on a contact plate on the roll. The Pt1000 are directly connected to the microprocessor board.

To prevent overheating when there is a malfunction of the Pt1000 or the microprocessor board,

a maximum temperature switch is placed, which switches off the power of the relay of the elements or the power of the gas control unit.

temp2: left sensor

temp1: right sensor

44

Page 44
Image 44
Alliance Laundry Systems CI 1650/325 Description of the control system, General description of the control system